Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
Search Results "Freight Elevator"
Commonly Searched Documents
-
1131A.2 Changes greater than ½ inch
-
4.1.3(5)*
If more than one elevator is provided, each full passenger elevator shall comply with 4.10....
-
4.10.5 RAISED CHARACTERS ON HOISTWAY ENTRANCES
All elevator hoistway entrances shall have raised floor designations provided on both jambs. The centerline of the characters shall be 60 in (1525 mm) from the floor....
-
§ 36.404 Alterations: Elevator exemption.
[See subsections ...]
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
Section 2. Covered multifamily dwellings
multifamily dwellings" or "covered multifamily dwellings subject to the Fair Housing Amendments" means buildings consisting of four or more dwelling units if such buildings have one or more elevators...
-
4.10.5 Raised and Braille Characters on Hoistway Entrances
All elevator hoistway entrances shall have raised and Braille floor designations provided on both jambs. The centerline of the characters shall be 60 in (1525 mm) above finish floor....
-
Elevator Exception 1—Section 206.2.3 of the 2010 Standards
Exception 1 to Section 206.2.3 of the 2010 Standards contains an elevator exception for private buildings or facilities that are less than three stories or that have less than 3,000 square...
-
408.2.3 Hoistway Signs
Signs at elevator hoistways shall comply with 407.2.3.1....
-
408.2.3 Hoistway Signs
Signs at elevator hoistways shall comply with 407.2.3.1....
-
§ 36.304(b)(6)
(6) Adding raised markings on elevator control buttons;...
-
Sec.36.304(b)(6)
(6) Adding raised markings on elevator control buttons;...
-
11B-408.2.3 Hoistway signs
Signs at elevator hoistways shall comply with Section 11B-407.2.3.1....
-
11B-408.2.3 Hoistway signs
Signs at elevator hoistways shall comply with Section 11B-407.2.3.1....
-
11B-408.2.3 Hoistway signs
Signs at elevator hoistways shall comply with Section 11B-407.2.3.1....
-
408.2.3 Hoistway Signs
Signs at elevator hoistways shall comply with 407.2.3.1....
-
11B-407.4.8.2 Audible indicators
Audible indicators shall comply with Section 11B-407.4.8.2.
-
11B-407.4.3 Platform to hoistway clearance
The clearance between the car platform sill and the edge of any hoistway landing shall be 1¼ inch (32 mm) maximum.
-
11B-411.2.1.3 Arrangement
Hall call console arrangement of required features shall comply with Section 11B-411.2.1.3.
-
11B-411.2.1.4 Additional features
Hall call console additional features, if provided, shall comply with Sections 11B-309 and 11B-411.2.1.4.
-
11B-411.2.1 Hall call consoles
Hall call consoles shall comply with Sections 11B-411.2.1 and 11B-309.
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions.
-
11B-411.4.7.2 Location
Raised characters or symbols and Braille designations shall comply with Section 11B-407.4.7.1.2.
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception:...