In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
Search Results "Entry Point"
-
608.3.3 Alternate Roll-In Type Shower Compartments
-
407.2.3.1 Floor Designation
A tactile star shall be provided on both jambs at the main entry level. Figure 407.2.3.1 Floor Designations on Jambs of Elevator Hoistway Entrances...
-
Door King Inc. 1837 PC Programmable IM Server Overview
Requires the Registered User plan or above. Login!
-
11B-407.3.4 Door and signal timing
the following equation: T = D/(1.5 ft/s) or T = D/(457 mm/s) = 5 seconds minimum where T equals the total time in seconds and D equals the distance (in feet or millimeters) from the point...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Power Chair
target shelf in the forward reach direction for a given (a) height from the floor (shown the vertical axis) and (b) offset distance (shown on the horizontal axis) from the forward-most point...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Manual Wheelchair
target shelf in the forward reach direction for a given (a) height from the floor (shown the vertical axis) and (b) offset distance (shown on the horizontal axis) from the forward-most point...
-
11B-407.3.4 Door and signal timing
the following equation: T = D/(1.5 ft/s) or T = D/(457 mm/s) = 5 seconds minimum where T equals the total time in seconds and D equals the distance (in feet or millimeters) from the point...
-
M302.2.3 Size
The size of transfer surfaces shall be measured from center points of their opposing sides....
-
R309.5.2 Displays and Information
Displays and information shall be visible from a point located 1.0 m (3.3 ft) maximum above the center of the clear space in front of the parking meter or parking pay station....
-
Trailhead
For purposes of the FSORAG and FSTAG, a trailhead is an outdoor space that is designated by an entity responsible for maintaining or administering the trail to serve as an access point to...
-
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST
site characteristics result in a difference in finished grade elevation exceeding 30 inches (762 mm) and 10 percent measured between an entrance and all vehicular or pedestrian arrival points...
-
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST
site characteristics result in a difference in finished grade elevation exceeding 30 inches (762 mm) and 10 percent measured between an entrance and all vehicular or pedestrian arrival points...
-
(4) Adjustability: Method of Measurement
The MDE Advisory Committee concurred with those comments recommending that the measurement be made with the upholstery in a static condition to ensure a consistent point of measurement....
-
Sample Documents
Editor's Note The following link points to the documents referenced above: http://www.adaactionguide.org/resources#sampledocuments Grievance Procedure - long and short versions...
-
11B-216.6 Entrances
Directional signs are needed where the accessible route diverges from the route for the general public and should be located at decision points (for example where the path to the stairs...
-
11B-216.6 Entrances
Directional signs are needed where the accessible route diverges from the route for the general public and should be located at decision points (for example where the path to the stairs...
-
§ 382.40a Boarding assistance for large aircraft
operations with aircraft having a seating capacity of 31 or more passengers at airports with 10,000 or more annual enplanements, in any situation where passengers are not boarded by level-entry...
-
Section 37.131 Service Criteria for Complementary Paratransit Service Area
The rail system would provide paratransit service from any point in one circle to any point in any other circle....
-
703.5.8 Character Spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces....
-
Grab Bar Height
Commenters pointed out the proposed rule was not clear on whether the height of grab bars was to be measured to the top or to the centerline. Response....
-
703.5.8 Character Spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces....
-
T702.6 Character Spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces....
-
T502.2 Doorways with Lifts, Ramps or Bridgeplates
Vertical clearance shall be measured from the inside finished edge of the door opening to the highest point of the deployed lift, ramp or bridgeplate below....
-
Trailhead
For the purpose of the FSTAG a trailhead is an outdoor space that is designated by the entity responsible for administering or maintaining the trail to serve as a primary access point to...