The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
Search Results "Door Clear Width"
Commonly Searched Documents
-
1132A.5.2 Strike edge maneuvering space at doors
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm).
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm).
-
4.13.1 General
Doors required to be accessible by 4.1 shall comply with the requirements of 4.13....
-
4.13.1 GENERAL
Doors required to be accessible by 4.1 shall comply with the requirements of 4.13....
-
903.2 Clear Floor or Ground Space
Clear floor or ground space complying with 305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
903.2 Clear Floor or Ground Space
Clear floor or ground space complying with 305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
In-swinging Bathroom Doors
The commenter recommended that in-swinging doors be prohibited unless there is sufficient internal bathroom space, exclusive of the swing of the door, which allows either a five foot turning...
- PC Doors Pocket Door E-Z Closer
-
11B-1002.5.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the amusement ride seats designed for transfer....
-
11B-1002.5.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the amusement ride seats designed for transfer....
-
11B-1002.5.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the amusement ride seats designed for transfer....
-
4.6.4 Clear Floor or Ground Space
The clear floor or ground space for telescopes and periscopes shall be at least 36 inches (915 mm) by 48 inches (1220 mm) positioned for forward approach to the telescope or periscope, and...
-
1132A.6 Closer-effort to operate doors
1132A.6 Closer-effort to operate doors....
-
7b.
Is the door hardware (e.g., lever, pull, push, panic bar) usable with one hand, without tight grasping, pinching, or twisting of the wrist, to allow people who may not be able to easily...
-
4.1.3(7)(a)
(a) At each accessible entrance to a building or facility, at least one door shall comply with 4.13....
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to hinged...
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to hinged...
-
Best Practice Recommendations for Layout Planning
A six foot width (72 inches) is recommended whenever feasible....
-
Feature 2 - Routes to the Building Entrance
Feature 2 - Routes to the Building Entrance Accessible routes connect accessible onsite features (e.g., bus stop, parking) to the building entrance. There must be at least...
-
F206.5.1 Entrances
Each entrance to a building or facility required to comply with F206.4 shall have at least one door, doorway, or gate complying with 404....
-
206.5.1 Entrances
Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
-
410.3 Clear Floor Space
410.3 Clear Floor Space. Clear floor space in platform lifts shall comply with 305....
-
F206.5.2 Rooms and Spaces
Within a building or facility, at least one door, doorway, or gate serving each room or space complying with these requirements shall comply with 404....