In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
Search Results "Transfer Wall"
Commonly Searched Documents
-
11B-608.3.3 Alternate roll-in type shower compartments
- Intensive Care Transfer with GH3 Ceiling Lift
- TelCom Red Wall Mount Weatherproof Audible Horn Strobe - 180 cd ASWP-2475W-FR
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
- Kohler Veil™ One-Piece Elongated Dual-Flush Wall-Hung Toilet With Reveal® Quiet-Close™ Seat
-
L-Shaped Seats: ADA Standard Section 610.3.2
Section 610.3.2 covers the current ADA Standards for L-shaped shower compartment seats.
-
11B-610.3.2 L-shaped seats
The rear edge of an L-shaped seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall....
-
Location: ADA Standard Section 409.4.6.2
Section 409.4.6.2 covers the current ADA Standards for the location of the car controls in private residence elevators.
-
11B-409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall....
- Neo-Metro Commercial Wall Mounted Pat Basin Featuring Dyson® Airblade™ Tap/Hand Dryer
-
A MINIMUM HIGHEST POINT STANDARD OF 19 INCHES IS CONSISTENT WITH EXISTING ACCESSIBILITY STANDARDS
Permanent seats shall be 15 inches (380 mm) minimum in depth and shall extend from the back wall to or beyond the outer edge of the bathtub....
-
11B-604.5 Grab bars
Grab bars shall be provided on the side wall closest to the water closet and on the rear wall....
-
Standard Roll-In Type Shower Compartments: ADA Standard Section 608.5.2
Section 608.5.2 covers the current ADA Standards for controls in standard roll-in type shower compartments.
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.5.3
Section 608.5.3 covers the current ADA Standards for controls in alternate roll-in type shower compartments.
-
G. Sleeping Areas
An accessible route is needed to provide access to each accessible cot and a clear space at least 36 inches wide is needed along the side of the cot to make it possible to transfer between...
-
Haws Barrier-Free Chilled Wall Mount Fountain H1001.8HPS
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley Imperial Wall-Mount Lavatory TL-18 Plan
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Haws Barrier-Free Chilled Wall Mount Fountain H1001.8
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Haws Barrier-Free Chilled Wall Mount Fountain H1109.8
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-608.5.3 Alternate roll-in type shower compartments
and 27 inches (686 mm) maximum from the seat wall or shall be located on the back wall opposite the seat 15 inches (381 mm) maximum, left or right of the centerline of the seat....
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
11B-608.5.2 Standard roll-in type shower compartments
) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
Size: ADA Standard Section 604.8.1.1
Section 604.8.1.1 covers the current ADA Standards for the size of wheelchair accessible compartments.
- Murdock Manufacturing Wall Hung Toilet, Rear Mount