Terry, You should identify the minimum dimensions of the clear floor space at the Lav.
Search Results "Toe Clearance"
Commonly Searched Documents
-
Clear floor space at Lav
-
602 Drinking Fountains
Substantive changes to this section include: removal of references to water coolers (602.1) requiring all wheelchair accessible drinking fountains to provide knee and toe...
-
BS8300:2001 Research
They include information on space required for “kneeholes,” reaching abilities of wheeled mobility users, clear floor area space requirements and maneuvering clearances....
-
805 Medical Care and Long-Term Care Facilities
Commenters opposed this requirement, noting that it is inconsistent with specifications for wheelchair turning space in section 304 which recognize knee and toe clearances for specified...
-
Wheelchair Turning Space [4.2.3]
Overlapping Fixed Elements Fixed elements can overlap turning space if required knee and toe clearances are provided....
-
Kitchens, Kitchenettes, or Wet Bars [9.2.2(7)]
A forward approach to sinks (with knee and toe clearances below) is recommended for sinks that may be used more regularly or for extended periods of time, such as a kitchen in apartment-style...
-
304.3.2 T-Shaped Space
The space shall be permitted to include knee and toe clearance complying with 306 only at the end of either the base or one arm....
- Pilot Rock ART Series End Accessible Recycled Plastic Picnic Table With Arched Frame
-
Alterations and Water Closet Clearances in Single-User Toilet Rooms With In-Swinging Doors (Section-by-Section Analysis)
or bathing rooms to swing into the required turning space, provided that there is sufficient clearance space for the wheelchair outside the door swing....
- The Corada Shop
-
Grab bar clearance
Have local authorities accepted one-piece dispensers in toilet compartments that are recessed behind the horizontal grab bars? These units stick out ¼" or so. ANSI 117.1 allows it...
-
17. Maneuvering Clearances and Hardware
[See subsections ...]
-
Wall-Mounted Objects
Fixed elements or barriers can provide detection below objects not required to have knee or toe clearance....
-
Table Surface Height
Some commenters also recommended a higher minimum height of 29 inches instead of 28 inches to allow a more comfortable knee clearance. Response....
-
11B-805.6 Hand washing fixtures, lavatories and sinks
Handwashing fixtures, as sinks, are subject to Section 11B-306.2.3, Exception 1 which states" "The toe clearance shall extend 19 inches minimum under sinks required to be accessible by...
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—in-swinging doors (Req. # 32)
For the water closet clearance in single-user toilet rooms with the in-swinging door requirement (Req. #32), the expert panel determined that the primary beneficiaries would be persons who...
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—in-swinging doors (Req. # 32)
For the water closet clearance in single-user toilet rooms with the in-swinging door requirement (Req. #32), the expert panel determined that the primary beneficiaries would be persons who...
-
Table 1
include: drinking fountains, public toilet facilities, tables, counters, passenger loading zones, ramps, stairways, handrails, doors, doorways, gates, operable parts, clear spaces, knee and toe...
-
Wheeled Mobility Anthropometry Project
range specified in the 2004 ADA and ABA Accessibility Guidelines for certain architectural features that involve transfers and that the dimensions for wheelchair spaces, including knee and toe...
- Boost Your Business - Chapter 3 - Path of Travel
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Forward Approach Scooter
., toe, footrest)....
-
11B-805.6 Hand washing fixtures, lavatories and sinks
Handwashing fixtures, as sinks, are subject to Section 11B-306.2.3, Exception 1 which states" "The toe clearance shall extend 19 inches minimum under sinks required to be accessible by Section...
-
11B-805.6 Hand washing fixtures, lavatories and sinks
Handwashing fixtures, as sinks, are subject to Section 11B-306.2.3, Exception 1 which states" "The toe clearance shall extend 19 inches minimum under sinks required to be accessible by Section...