A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and...
Search Results "Single-Story Dwelling Unit (FHA)"
Commonly Searched Documents
-
11B-809.10.6.3 Floor space
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum.
-
Elements Within Picnic Units With Mobility Features [F245.2.5]
At least one of each type of element provided within picnic units with mobility features, including outdoor constructed features and parking spaces, must comply with the applicable technical...
-
11B-809.10.2 Number of complying bathing rooms and fixtures
One bathing room and one fixture of each type within the dwelling unit shall be designed to comply with the following: Maneuvering space in toilet, bathing and shower rooms shall...
-
F245.2.2 Picnic Facilities with More Than Two Picnic Units
Where picnic facilities contain more than two picnic units, at least 20 percent, but not less than two, of the picnic units shall provide mobility features complying with F245.2....
- Symmons Hand Shower T-600B-36-V
-
3.3.3 Identification of Accessible Picnic Units
Where not all picnic units are accessible, the picnic units that are accessible shall not be identified by signs at the individual units....
-
IV. Deeming 2010 Standards as an Alternative Accessibility Standard for Section 504 Compliance
entities that are subject to the requirements of title III of the ADA, 42 U.S.C. 12181–12189. 13 HUD’s scoping continues to apply regarding the required number of accessible residential dwelling...
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4 _|Operation|_. Controls and faucets shall be of a single-lever design. [2010 ADAS] 608.5 Controls. ...
-
4.20.6 SHOWER UNIT
A shower spray unit with a hose at least 60 in (1525 mm) long that can be used as a fixed shower head or as a hand-held shower shall be provided....
-
4.20.6 Shower Unit
A shower spray unit with a hose at least 60 in (1525 mm) long that can be used both as a fixed shower head and as a hand-held shower shall be provided....
-
1134A.1 General
All bathrooms, bathing and toilet facilities within covered multifamily dwelling units shall comply with this section....
-
1134A.1 General
All bathrooms, bathing and toilet facilities within covered multifamily dwelling units shall comply with this section....
-
Elevator Exemption (Preamble, Section-by-Section Analysis)
Congress, however, chose not to require elevators in new small buildings, that is, those with less than three stories or less than 3,000 square feet per story....
-
Elevator Exemption (Section-By-Section Analysis and Response to Comments)
Congress, however, chose not to require elevators in new small buildings, that is, those with less than three stories or less than 3,000 square feet per story....
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4 _|Operation|_. Controls and faucets shall be of a single-lever design. [2010 ADAS] 608.5 Controls....
-
11B-233.3.1.2.5 Public housing facility site impracticality
The number of adaptable residential dwelling units required in non-elevator building public housing facilities shall be determined in accordance with Chapter 11A, Section 1150A.1....
-
11B-608.4 Seats
Exception: In residential dwelling units, seats shall not be required in shower compartments provided that reinforcement has been installed in walls so as to permit the installation of...
-
11B-608.4 Seats
Seats shall comply with 610 Exception: In residential dwelling units, seats shall not be required in shower compartments provided that reinforcement has been installed in walls so as...
-
11B-608.4 Seats
Exception: In residential dwelling units, seats shall not be required in shower compartments provided that reinforcement has been installed in walls so as to permit the installation of seats...
-
1134A.1 General
All bathrooms, bathing and toilet facilities within covered multifamily dwelling units shall comply with this section....
-
4.34.5.4 BATHTUBS
If a bathtub is provided, then it shall have the following features:
-
11B-608.6 Shower spray unit and water
SECTION TITLE NOTES 11B-608.6 Shower spray unit and water....
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall. A floor space 48 inches (1219 mm) wide minimum by 36 inches (914...