Doors shall not swing into the clear floor space required for any fixture.
Search Results "Single-Story Dwelling Unit (FHA)"
-
4.34.5.1 DOORS
-
1132A.3, Item 3
3. Swinging doors shall be capable of opening at least 90 degrees.
-
1132A.3, Item 5
5. A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle...
-
1132A.3, Item 2
2. Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed...
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
-
11B-809.10.7 Water closets
Water closets required by Section 11B-809.10 shall comply with this section.
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.
-
11B-809.10 Toilet and bathing rooms
[See subsections ...]
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope.
-
1132A.1 Primary entry doors and required exit doors
., entry or exit doors which open from the covered multifamily dwelling unit into a corridor, hallway or lobby, or directly to the outside)....
-
804.3 Kitchen Work Surface (Exception)
804.3 Kitchen Work Surface (Exception) This section requires at least one work surface to be provided at kitchen counters in residential dwelling units required to provide mobility features...
-
11B-233.1 General
Public housing facilities with residential dwelling units available for public use shall comply with Section 11B-233....
-
213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms....
-
11B-213.2.1 Unisex (single-use or family) toilet and unisex bathing rooms
Unisex toilet rooms shall contain not more than one lavatory, and not more than two water closets without urinals or one water closet and one urinal. Unisex bathing rooms shall...
-
1(2) Site impracticality
Covered multifamily dwellings with elevators shall be designed and constructed to provide at least one accessible entrance on an accessible route, regardless of terrain or unusual characteristics...
-
11B-206.6 Elevators
Elevators complying with Section 11B-408 or 11B-409 shall be permitted in multi-story residential dwelling units....
-
Appendix to May 23, 2014 Document
Exception 1 to Section 206.2.3 Multi-Story Buildings and Facilities 2010 Standards at Section 206.2.3 without Exception 1. 10....
-
4.1.3(12) Storage, Shelving and Display Units
(12) Storage, Shelving and Display Units:...
-
11B-604.5 Grab bars
Grab bars shall not be required to be installed in a toilet room for a single occupant accessed only through a private office and not for common use or public use provided that reinforcement...
-
F244.2 Camping Units with Mobility Features
Where different types of camping units are provided (e.g., camping units for recreational vehicles only; camping units for tent camping only; and camping units with camp shelters), Table...
-
A. Scoping Requirements for Units with Mobility Features
Scoping Requirements for Units with Mobility Features The ADA and ABA Accessibility Guidelines require at least 5 percent of the residential dwelling units in a facility to provide mobility...