Curbs [4.21.7] Curbs are limited to ½ inch (measured from the room floor and the shower floor) so as not to interfere with entry to the shower....
Search Results "One Step Entry"
-
Curbs [4.21.7]
-
1132A.4, Item 1
., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change in height between floor surfaces....
-
11B-203.14 Raised diving boards and diving platforms
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
11B-203.14 Raised diving boards and diving platforms
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
1009.6.1 Pool Stairs
EXCEPTION: Pool step riser heights shall not be required to be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum provided that riser heights are uniform....
-
1009.6.1 Pool Stairs
EXCEPTION: Pool step riser heights shall not be required to be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum provided that riser heights are uniform....
-
§ 38.63(a) Requirement
Suitable devices or systems shall be provided to prevent, deter or warn individuals from inadvertently stepping off the platform between cars....
-
11B-203.11 Water slides
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders or other means of reaching the raised elements...
-
Public Sector (Government) Facilities
between stories is required in multi-story government facilities subject to title II of the ADA except those with no more than two stories where the inaccessible story above (or below) the entry...
-
1132A.4 Level floor or landing
Primary entry doors, required exit doors or secondary exterior doors with changes in height between the interior surface or floor level and the exterior surface or floor level shall comply...
-
M303.2.6 Edge Protection
platform raised more than 1 ½ inches (38 mm) in height, edge protection 2 inches (51 mm) high minimum measured from the surface of the platform shall be provided on each side not providing entry...
- TownSteel TDG129 Door Guard
-
§27.11(c)(2)
(2) A recipient shall, within 180 days from the effective date of this part, after consultation at each step in paragraphs (c)(2) (i)-(iii) of this section with interested persons, including...
-
§ 38.31(b)
(b) Other stepwells and doorways, including doorways in which lifts or ramps are installed, shall have, at all times, at least 2 foot-candles of illumination measured on the step tread,...
- Caroma® USA Sydney Smart 305 Easy Height Elongated 1 Piece Toilet
-
M303.3.1 Vertical (Section-by-Section Analysis)
The MDE NPRM proposed that for equipment with a change in level at the entry to the wheelchair space, level changes of up to ¼ inch high are permitted to be vertical....
-
404.2.4 Maneuvering Clearances
EXCEPTION: Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door....
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
F. Clear Width
Do all entry doors to accessible guestrooms and other interior doors (except doors on shallow closets) allow at least 32" of clear passage width to accommodate persons who use wheelchairs...
-
H6
If the entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the door swing?...
-
A4.3.11.4 Two-way Communication
requirement could be satisfied with something as simple as a button in the area of rescue assistance that lights, indicating that help is on the way, when the message is answered at the point of entry...
-
Can platform lifts be locked?
The Standards require “unassisted” entry and exit from lifts (§410.1)....
-
§ 38.161 Moveable aisle armrests
including all moveable or removable seats at wheelchair or mobility aide securement locations, shall have an armrest on the aisle side which can be raised, removed, or retracted to permit easy entry...
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....