No fewer than one shelf shall be provided in close proximity to the changing table at 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor.
Search Results "Non-Housing Facility"
-
11B-813.2.6 Shelf
-
11B-813.2.5 Coat hook
No fewer than one coat hook shall be provided in close proximity to the changing table and within one of the reach ranges specified in Section 11B-308.
-
1006 Golf Facilities
[See subsections ...]
-
1006 Golf Facilities
[See subsections ...]
-
11B-216.5.3.2 Additional signs
Signs within parking facilities containing parking spaces complying with Section 11B-502 shall comply with Section 11B-502.8....
-
11B-216.5.3.2 Additional signs
Signs within parking facilities containing parking spaces complying with Section 11B-502 shall comply with Section 11B-502.8....
-
Commercial Facilities in Private Residences (Section-By-Section Analysis and Response to Comments)
The Department is aware that the statutory definition of "commercial facility'' excludes private residences because they are "expressly exempted from coverage under the Fair Housing Act...
-
11B-604.5 Grab bars
In detention or correction facilities, grab bars shall not be required to be installed in housing or holding cells that are specially designed without protrusions for purposes of suicide...
-
11B-604.5 Grab bars
In detention or correction facilities, grab bars shall not be required to be installed in housing or holding cells that are specially designed without protrusions for purposes of suicide...
-
405.2 Slope (Exception 2), 405.6 Rise (Exception)
The floor level of emergency transportable housing units is typically elevated 36 inches above the ground....
-
Long Term Care / Nursing Homes
The degree of medical treatment or care provided at a facility may need to be taken into account since this section is not intended to cover facilities that provide residential but little...
-
Turning Space: ADA Standard Section 1010.1
A circular turning space 60 inches (1525 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
11B-1010.1 Turning space
A circular turning space 60 inches (1524 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
11B-1010.1 Turning space
A circular turning space 60 inches (1524 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
§ 37.9(c)(2)
(2) Existing buildings and facilities that are not altered after November 29, 2006, and which comply with the former Appendix A to this part, are not required to be retrofitted to comply...
-
11B-235 Recreational boating facilities
[See subsections ...]
-
11B-235 Recreational boating facilities
[See subsections ...]
-
Visible Alarms—Exception to Section 215.1 of the 2010 Standards
Section 215.1 includes a new exception for visible alarms in the alteration of existing facilities, providing that visible alarms must be installed only when an existing fire alarm system...
-
§ 35.151(k) Detention and correctional facilities.
(k) Detention and correctional facilities....
-
Pool Lifts
Pool Lifts Pool lifts must be located where the water level is not deeper than 48 inches. This provides the opportunity for someone to provide assistance from a standing position...
-
Seat Height
Seat Height The lift must be designed so that the seat will make a stop between a minimum of 16 inches and maximum of 19 inches (measured from the deck to the top of the seat...
-
Submerged Depth
Submerged Depth Lifts must be designed so that the seat will submerge to a minimum of 18 inches below the stationary water level. This will ensure buoyancy for the person on the...
-
Lifting Capacity
Lifting Capacity Lifts must have the capability of supporting a minimum weight of 300 pounds and be capable of sustaining a static load that is at least 1.5 times the rated load....
-
T505 Fare Collection Devices
[See subsections ...]