Clear floor space in front of bathtubs shall be as shown in Fig. 33....
Search Results "Ground Floor Exit"
-
4.20.2 Floor Space
-
4.20.2 FLOOR SPACE
Clear floor space in front of bathtubs shall be as shown in Fig. 33....
-
Golf Courses: ADA Standard Section 238.2
Section 238.2 covers scoping requirements in the current ADA Standards for golf courses.
-
11B-238.2 Golf courses
Golf courses shall comply with Section 11B-238.2.
-
11B-238.2 Golf courses
Golf courses shall comply with Section 11B-238.2.
-
Zurn Z1457 Floor Access Cover
Requires the Premium User plan or above. (Login or upgrade your account!)
-
1007.8 Two-way communication
A two-way communication system shall be provided at the elevator landing on each accessible floor that is one or more stories above or below the story of exit discharge complying with Sections...
-
11B-502.4 Floor or ground surfaces
Advisory 11B-502.4 Floor or ground surfaces. Access aisles are required to be nearly level in all directions to provide a surface for wheelchair transfer to and from vehicles....
-
9.5.2(2)(a)
(a) at least one public entrance shall allow a person with mobility impairments to approach, enter and exit including a minimum clear door width of 32 in (815 mm)....
-
Inpro Corporation JointMaster® AR Series Seal Expansion Joint Systems
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Inpro Corporation JointMaster® DR Series Seal Expansion Joint Systems
Requires the Premium User plan or above. (Login or upgrade your account!)
-
3. Desk clear floor space
Desk clear floor space: If provided, desks and writing tables need to have a 30-inch by 48-inch clear floor space that extends 19 inches under the desk and any fixed seat needs to be removable...
-
Inpro Corporation JointMaster® 316 Single Sightline for Carpet Floor Expansion Joint Covers Floor to Wall
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...
-
4.18.3 Clear Floor Space
A clear floor space 30 in by 48 in (760 mm by 1220 mm) shall be provided in front of urinals to allow forward approach....
-
4.18.3 CLEAR FLOOR SPACE
A clear floor space 30 in by 48 in (760 mm by 1220 mm) shall be provided in front of urinals to allow forward approach....
-
1009.7 Exterior areas for assisted rescue
Where the exit discharge does not include an accessible route from an exit located on the level of exit discharge to a public way, an exterior area of assisted rescue shall be provided on...
-
1009.7 Exterior areas for assisted rescue
Where the exit discharge does not include an accessible route from an exit located on the level of exit discharge to a public way, an exterior area of assisted rescue shall be provided on...
-
11B-206.2.17.1 Ground level and elevated play components
The accessible route shall connect ground level play components required to comply with Section 11B-240.2.1 and elevated play components required to comply with Section 11B-240.2.2, including...
-
11B-206.2.17.1 Ground level and elevated play components
The accessible route shall connect ground level play components required to comply with Section 11B-240.2.1 and elevated play components required to comply with Section 11B-240.2.2, including...
-
11B-206.2.17.1 Ground level and elevated play components
The accessible route shall connect ground level play components required to comply with Section 11B-240.2.1 and elevated play components required to comply with Section 11B-240.2.2, including...
- Pilot Rock CN-TR-52 Tilting Trash Receptacle
-
Clear Floor Space [4.16.2]
Clear Floor Space [4.16.2] ADAAG (Figure 28) specifies the amount of space required at an accessible toilet, not the minimum room size, which must also include turning space, clear floor...