(3) Major interchange points with other transportation modes, including stations connecting with major parking facilities, bus terminals, intercity or commuter rail stations, passenger vessel...
Search Results "Entry Point"
-
§ 37.47(b)(3)
-
§ 37.51(b)(3)
(3) Major interchange points with other transportation modes, including stations connecting with major parking facilities, bus terminals, intercity or commuter rail stations, passenger vessel...
-
11B-610.4 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
Door King Inc. 1837 PC Programmable IM Server Overview
Requires the Registered User plan or above. Login!
-
11B-804.2.1 Pass through kitchen
Pass through kitchens shall have two entries. FIGURE 11B-804.2.1 PASS THROUGH KITCHENS...
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
-
11B-208.3.3.2
An accessible route from the residential dwelling unit's primary entry door to the vehicular entrance at the garage....
-
407.2.3.1 Floor Designation
A tactile star shall be provided on both jambs at the main entry level....
-
4.13.6 MANEUVERING CLEARANCES AT DOORS
Entry doors to acute care hospital bedrooms for in-patients shall be exempted from the requirement for space at the latch side of the door (see dimension "x" in Fig. 25) if the door is at...
-
Q17. Does the ADA require that service animals be certified as service animals?
Covered entities may not require documentation, such as proof that the animal has been certified, trained, or licensed as a service animal, as a condition for entry....
-
E. GRIEVANCE PROCEDURE
Within three (3) months of the entry of this Consent Decree, the County will adopt the attached ADA Grievance Procedure, Attachment C, distribute it to all of its agencies, post it on its...
-
§ 38.73(d)(1) Requirements
The design of level-entry vehicles shall be coordinated with the boarding platform or mini-high platform design so that the horizontal gap between a vehicle at rest and the platform shall...
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area at the exterior side of the primary entry door and any required exit doors shall comply with Section 1126A....
-
11B-216.6 Entrances
Directional signs are needed where the accessible route diverges from the route for the general public and should be located at decision points (for example where the path to the stairs...
-
11B-216.6 Entrances
Directional signs are needed where the accessible route diverges from the route for the general public and should be located at decision points (for example where the path to the stairs...
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
609.8 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
609.8 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
609.8 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
1.2.2
1.2.2 Use datum dimensioning referenced to a primary or secondary control point on the construction site when the position of one item is particularly important....
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
11B-407.4.10.3 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, fastener, mounting device...
-
11B-407.3.4 Door and signal timing
the following equation: T = D/(1.5 ft/s) or T = D/(457 mm/s) = 5 seconds minimum where T equals the total time in seconds and D equals the distance (in feet or millimeters) from the point...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Power Chair
target shelf in the forward reach direction for a given (a) height from the floor (shown the vertical axis) and (b) offset distance (shown on the horizontal axis) from the forward-most point...