1132A.5.2 Strike edge maneuvering space at doors. The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
Search Results "Door Operator"
-
1132A.5.2 Strike edge maneuvering space at doors
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]
-
Automatic and Power-Assisted Doors and Gates [§404.3]
Automatic and Power-Assisted Doors and Gates [§404.3] Doors are not required to be automated, but must comply when provided....
- CS Pocket Insert Track Demo
-
707.3 Operable Parts
707.3 Operable Parts. Operable parts shall comply with 309....
-
D3
[ADA Standards § 4.13.9] Yes No If No, leave door propped open, add new accessible hardware, or adapt/replace hardware. ...
-
11B-307.4 Vertical clearance
Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground....
-
11B-307.4 Vertical clearance
Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground. ...
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
302.8 With Limited Reach and Strength
Where a manual mode of operation is provided, ICT shall provide at least one mode of operation that is operable with limited reach and limited strength....
-
302.8 With Limited Reach and Strength
Where a manual mode of operation is provided, ICT shall provide at least one mode of operation that is operable with limited reach and limited strength....
-
407.12.3.2.1 Height
The height of the operable part shall conform to Table 407.12.3.2.1....
-
407.12.3.2.1 Height (Section-by-Section Analysis)
407.12.3.2.1 Height (Section-by-Section Analysis) This section, presented in tabular form (Table 407.12.3.2.1), proposes alternative maximum heights for operable parts with obstructed...
-
Controls [4.15.4]
Controls [4.15.4] Controls must be operable with one hand and not require tight grasping, pinching, or twisting of the wrist to operate....
- Motorized Lift & Slide Door System by Panda
-
Controls [9.2.2(5)]
Controls [9.2.2(5)] All controls in accessible units, sleeping rooms, and suites must comply with 4.27, which provides specifications for clear floor space, height of operable controls...
-
707.3 Operable Parts
Operable parts shall comply with 309. Unless a clear or correct key is provided, each operable part shall be able to be differentiated by sound or touch, without activation....
-
707.3 Operable Parts
Operable parts shall comply with 309. Unless a clear or correct key is provided, each operable part shall be able to be differentiated by sound or touch, without activation....
-
Operable Parts
Operable Parts The Department sought comment on certain characteristics of operable parts, including the following: Identification—The Department proposed to require that the operable...
-
407.1 General
Where provided, operable parts used in the normal operation of ICT shall conform to 407....
-
9.5.2(2)(b)
(b) sleeping space for homeless persons as provided in the scoping provisions of 9.1.2 shall include doors to the sleeping area with a minimum clear width of 32 in (815 mm) and maneuvering...