installments, issued May 7, 2007, include: Chapter 5, Website Accessibility Under Title II of the ADA (HTML) | (PDF) Chapter 5, Addendum: Title II Checklist (HTML) | (PDF) Chapter 6, Curb...
-
5.8.1.2.3 Double Ramped Entry - Edge Protection on the Platform sides Recommendations
5.8.1.2.3 Double Ramped Entry - Edge Protection on the Platform sides Recommendations The Committee recommends a minimum two-inch high edge protection on both sides of the platform for...
-
5.8.1.2.2 Single Ramped Entry – Edge Protection on the Platform and Platform Sides
5.8.1.2.2 Single Ramped Entry – Edge Protection on the Platform and Platform Sides....
-
4.1.2(5)
EXCEPTION: Accessible ramps complying with 4.8 or, if no other alternative is feasible, accessible platform lifts complying with 4.11 may be used in lieu of an elevator....
-
11B-505.6 Gripping surface
The bottoms of handrail gripping surfaces shall not be obstructed for more than 20 percent of their length....
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
505.6 Gripping Surface
The bottoms of handrail gripping surfaces shall not be obstructed for more than 20 percent of their length....
-
11B-505.6 Gripping surface
The bottoms of handrail gripping surfaces shall not be obstructed for more than 20 percent of their length....
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
505.6 Gripping Surface
The bottoms of handrail gripping sufaces shall not be obstructed for more than 20 percent of their length....
-
505.6 Gripping Surface
The bottoms of handrail gripping surfaces shall not be obstructed for more than 20 percent of their length....
-
11B-505.6 Gripping surface
The bottoms of handrail gripping surfaces shall not be obstructed for more than 20 percent of their length....
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
- citEcar ADA Electric Shuttle 11P 1WC
- citEcar ADA Enclosed Shuttle 11P 1WC
-
Cross Slope and Surfaces [4.8.6]
Ramp surfaces must comply with requirements for ground and floor surfaces and be "stable, firm, and slip-resistant." A specific level of slip-resistance is not mandated....
- EZ Dock EZ TRAIL® Modular Walkway
-
11B-406.2.2 Sides of curb ramps
Where provided, curb ramp flares shall not be steeper than 1:10. FIGURE 11B-406.2.2 ‡‡ SIDES OF CURB RAMPS...