start as low as 1.28 gpf/4.8 Lpf Water conservation is aided by the ADA-compliant, non-hold-open handle, which prevents toilet from exceeding intended flush volume Flush accuracy is controlled...
Search Results "Bathtub Control"
Commonly Searched Documents
- Sloan Royal® Exposed Water Closet Flushometer
- Selectronic Exposed Hard-Wired AC Toilet 1.1 gpf Flush Valve
- Lutron Sivoia QS Wireless Shading System
- Automatic Curtain Ltd. Automatic Roman Shade System III
-
11B-608.6 Shower spray unit and water
The shower spray unit shall have an on/off control with a non-positive shut-off....
-
§ 1194.23(k)
(k) Products which have mechanically operated controls or keys, shall comply with the following:...
- DEL Motorized Solutions Electric Roman Shades
- Delta H2Optics Exposed Flush Valve 81T201BTA
-
11B-812.10.2 Operable parts
Operable parts and charging cord storage shall comply with Section 11B-309.
-
608.5.2 Standard Roll-In Type Shower Compartments
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
- DEL Motorized Solutions Motorized Vertical Shades
-
Scoping [4.1.3(13)]
Controls and operating mechanisms intended for use only by employees for job-related tasks are not required to comply (although compliance will help accommodate employees)....
- BEA Inc. Pneumatic Push Button Automatic Door Access (Push to Exit)
- BEA Inc. Piezo Push Button Heavy Duty Door Actuator (Push to Exit)
- Wikk AccessAbility ™ “Long Ranger” 868 Mhz Transmitters and Receivers
- Behavioral Safety Products #SV230 Ligature Resistant Shower Valve, Handle, & Escutcheon Plate
- DEL Motorized Solutions Motorized Rolling Shades
-
Section H: Lifts
(§§410.3, 305.3) H4 Are the controls for the lift no higher than 48"?...
-
§ 38.107(a)(4)
(4) Faucets and flush controls shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist....
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, operable parts of controls and faucets shall be installed on the back wall of the compartment adjacent to the seat wall 19 inches (483 mm) minimum...
-
224.2 Guest Rooms with Mobility Features
224.2 Guest Rooms with Mobility Features. In transient lodging facilities, guest rooms with mobility features complying with 806.2 shall be provided in accordance with Table...
-
F224.2 Guest Rooms with Mobility Features
In transient lodging facilities, guest rooms with mobility features complying with 806.2 shall be provided in accordance with Table F224.2. [ECTCR UFAS 4.1.4(11)(a) depending on...
-
224.2 Guest Rooms with Mobility Features
In transient lodging facilities, guest rooms with mobility features complying with 806.2 shall be provided in accordance with Table 224.2. EXCEPTIONS: 1. Facilities on a...
-
11B-609.3 Spacing
Exceptions: The space between the grab bars and shower controls, shower fittings, and other grab bars above shall be permitted to be 1½ inches (38 mm) minimum....