This can lead to neighborhood as well as user concerns, since excessive volume will mask other sounds that are important to pedestrians who are blind (such as the sound of traffic surges...
Search Results "User Control"
Commonly Searched Documents
-
Issue 1: APS volume
-
22.1 Q. Must the switches on range hood kitchen ventilation fans be in accessible locations?
(See Guidelines for Requirement 5 and Controls for Ranges and Cooktops at 56 FR 9490 and 9492, March 6, 1991, or 24 CFR Ch. I, Subch. A, App. III.)...
-
Chapter 4: Implications for standards and design
[See subsections ...]
- Symmons Duro® Tub Shower System 3S603-H321-V
- Delta Monitor® 13 Series Tub and Shower Trim - Push Button Diverter
- Why Moen Commercial Products?
-
Trash, Recycling, and Other Essential Containers
Ensure controls and operating mechanisms for containers comply with the technical requirements for reach ranges and operability specified in ABAAS, sections 308 and 309, and explained in...
-
§27.71(k)(3)(ii) Timing.
Where a timed response is required, the user must be alerted visually and by touch or sound and must be given the opportunity to indicate that more time is required;...
-
§ 27.71(k)(3)(ii) Timing
Where a timed response is required, the user must be alerted visually and by touch or sound and must be given the opportunity to indicate that more time is required;...
-
4.27.3* Height
The highest operable part of controls, dispensers, receptacles, and other operable equipment shall be placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6....
-
Operating Hardware
Operating Hardware Common Problem: The shape of the hardware on accessible doors, and on faucets, fixed lamps, drapery controls, and heating and air conditioning controls in spaces...
-
Issue 4: Wrong pole! …Wrong message!
Figure 7: Installation where APS are installed in wrong locations; both are too far from street they control and will be heard as closer to the other street. ...
-
220 and 707 Automatic Teller Machines and Fare Machines
220 and 707 Automatic Teller Machines and Fare Machines Section 707 of the 2010 Standards adds specific technical requirements for speech output, privacy, tactilely-discernible input controls...
-
C. Toilet Rooms:
PSE shall provide at least nine (9) 60-inch wide accessible toilet compartments, located in multi-user toilet rooms, and at least six (6) accessible water closets with 60-inch wide...
-
Issue 14: Inspection of contractor’s work - Beware of field changes!
Figure 20: Deaf-blind user stands with his hand on the original APS to feel the vibration in order to know when to begin to cross....
-
A4.27.3 HEIGHT
A6 further illustrates mandatory and advisory control mounting height provision for typical equipment....
-
11B-809.10.5.1 Clear floor space
Controls shall be located on the wall at the foot of the bathtub. The edge of the clear floor space shall be flush with the control wall surface....
-
Tactile arrow
Tactile arrow The tactile arrow on the device must be aligned with the direction of travel on the crosswalk and point toward the street crossing that the pushbutton controls and signals...
- Moen® Chrome PosiTemp® Shower Kit
-
Chapter 3: Study findings
[See subsections ...]
-
Issue 11: Good vibrations (vibrotactile indications)
The vibrotactile indication can be turned off in some devices by a setting either on the control board or within the PDA device. Check settings to be sure vibration is on....
-
§382.57(c)(6)(ii) Alphabetic keys
(ii) Alphabetic keys. Alphabetic keys must be arranged in a QWERTY keyboard layout. The “F” and “J” keys must be tactilely distinct from the other keys.
-
1. Accessible toilet
1. Accessible toilet with rear and side grab bars, clear floor space for wheelchair transfer, and an accessible flush valve.
-
1630.16(e)
(e) Infectious and communicable diseases; food handling jobs. --