Water closet seats shall be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat above the finish floor.
Search Results "Urinal Rim Height"
Commonly Searched Documents
-
11B-809.10.7.4 Seat height
-
5.8.2.1 Height of Breast Platform At Time of Measurement
5.8.2.1 Height of Breast Platform At Time of Measurement. All knee and toe clearances should be measured when the top of the breast platform is set at 34 inches above the floor....
-
M305.2.4.2 Non-Circular Cross Section
Transfer supports with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8...
-
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302 Description: Gripping surface hazards are sharp or abrasive elements that prevent an individual...
-
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The gripping surfaces of the transfer support must be free of...
-
36 CFR Part 1195 Proposed Accessibility Standards for Medical Diagnostic Equipment NPRM
February 8, 2012 UNITED STATES ACCESS BOARD A FEDERAL AGENCY COMMITTED TO ACCESSIBLE DESIGN 1331 F Street, N.W. Suite 1000 • Washington, D.C. 20004‒1111 (800) 872‒2253...
-
36 CFR Part 1195 Proposed Accessibility Standards for Medical Diagnostic Equipment NPRM - Preamble
February 8, 2012 UNITED STATES ACCESS BOARD A FEDERAL AGENCY COMMITTED TO ACCESSIBLE DESIGN 1331 F Street, N.W. Suite 1000 • Washington, D.C. 20004‒1111 (800) 872‒2253...
- American Standard Cadet 1.1 gpf FloWise Right Height Pressure Assisted Elongated Toilet 2467100
- Mayer-Rothschild Foundation: Determination of Grab Bar Specifications for Independent and Assisted Transfers in Residential Care Settings
-
407.12 Reach Height (Section-by-Section Analysis)
407.12 Reach Height (Section-by-Section Analysis) This section proposes requirements for the height of side and forward reaches that would enable persons using wheelchairs or other mobility...
-
1136A.1 Receptacle heights
Baseboard electrical outlets used in relocatable partitions, window walls or other electrical convenience floor outlets are not subject to the minimum height requirements....
-
407.8.3.2.1 Operable Part Height for ICT with Obstructed Forward Reach
The height of the operable part shall conform to Table 407.8.3.2.1....
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height. Edge protection is not required on platforms 1 ½ inches or less in height....
- American Standard Yorkville 1.1 gpf FloWise Right Height Elongated Pressure Assisted Toilet
- 2101KG HR Digital Platform Scale with Mechanical Height Rod
-
1136A.1 Receptacle heights
Baseboard electrical outlets used in relocatable partitions, window walls or other electrical convenience floor outlets are not subject to the minimum height requirements. 4....
-
SECTION 1136A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS
SECTION 1136A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS...
- 2101KL HR Digital Platform Scale with Mechanical Height Rod
-
5.8.2.6 Clearance Depth at Toe Height above the ground Recommendation
5.8.2.6 Clearance Depth at Toe Height above the ground Recommendation The Committee recommends 22 inches minimum clearance depth at toe height....
- American Standard Cadet 1.1 gpf FloWise Right Height Pressure Assisted Elongated Toilet 2467136
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations The Committee recommends that no edge protection be required on platforms of 1½ inches or less in height...
-
4.34.6.5(1)
(1) The sink and surrounding counter shall be mounted at a maximum height of 34 in (865 mm) above the floor, measured from the floor to the top of the counter surface, or shall be adjustable...
-
11B-226.3 Dining surfaces exceeding 34 inches in height
Where food or drink is served for consumption at a counter exceeding 34 inches (864 mm) in height, a portion of the main counter 60 inches (1525 mm) minimum in length shall be provided in...
-
11B-226.3 Dining surfaces exceeding 34 inches in height
Where food or drink is served for consumption at a counter exceeding 34 inches (864 mm) in height, a portion of the main counter 60 inches (1525 mm) minimum in length shall be provided in...