Outdoor ramps and their approaches shall be designed so that water will not accumulate on walking surfaces....
Search Results "Ramp Slope"
-
4.8.8 OUTDOOR CONDITIONS
-
Wading pools. (Section-by-Section Analysis)
Almost all commenters felt that during alterations a sloped entry should be provided unless it was technically infeasible to do so....
-
d-ii
Are handrails installed on both sides of each ramp segment? [ADA Standards § 4.8.5] Yes No...
-
f-ii
Are handrails installed on both sides of each ramp segment? [ADA Standards § 4.8.5] Yes No...
-
4b.
Is the ramp width, measured between handrails, at least 36 inches? [ADA Stds 4.8.3] Yes _____ No _____...
-
d-iii
Is the ramp width, measured between handrails, at least 36 inches? [ADA Standards § 4.8.3] Yes No...
-
C1-e
Where an accessible route crosses a curb, is a curb ramp provided? [ADA Standards § 4.3.8] Yes No...
-
f-iii
Is the ramp width, measured between the handrails, at least 36 inches? [ADA Standards § 4.8.3] Yes No...
-
1007.2, Item 8
Ramps complying with Section 1010, and Chapter 11A, Sections 1114A and 1122A, or Chapter 11B, 11B-405, as applicable....
-
1009.2, Item 8
Ramps complying with Section 1012, and Chapter 11A, Sections 1114A and 1122A, or Chapter 11B, 11B-405, as applicable....
-
4f.
Is a level landing, at least 60 inches by 60 inches, provided where a ramp changes direction? [ADA Stds 4.8.4] Yes _____ No _____...
-
4.8.5(5)
(5) Top of handrail gripping surfaces shall be mounted between 34 in and 38 in (865 mm and 965 mm) above ramp surfaces....
-
11B-505.1 General
Handrails provided along walking surfaces complying with Section 11B-403, required at ramps complying with Section 11B-405, and required at stairs complying with Section 11B-504 shall comply...
-
11B-705.1.2.2.2.2 Two entrance/exit points
Where the turning space has two entrance/exit points other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep at both entrance/ exit points, as measured...
-
405.10 Wet Conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
405.10 Wet Conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
405.10 Wet Conditions
405.10 Wet Conditions. Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
405.10 Wet Conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
405.7.4 Change in Direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum....
-
405.7.4 Change in Direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum....
-
R207.2 Alterations
In alterations where existing physical constraints prevent compliance with R207.1, a single diagonal curb ramp shall be permitted to serve both pedestrian street crossings....
-
503.4 Floor and Ground Surfaces
EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
4.8.5(2)
(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top and bottom of the ramp segment and shall be parallel with the floor or ground surface (see Fig...
- Atlantis Railing