Clear floor or ground space around a water hydrant shall be 48 inches (1220 mm) by 72 inches (1830 mm) with the long side of the space adjoining an outdoor recreation access route, trail...
Search Results "RERC Rec-Tech: Rehabilitation Engineering Research Center on Recreational Technologies"
-
4.7.6 Water Hydrant Clear Floor or Ground Space
- Department of Employment, Training & Rehabilitation’s (DETR) Bureau of Vocational Rehabilitation
-
Multi-Story Buildings and Facilities: ADA Standard Section 206.2.3
Section 206.2.3 covers the scoping requirements in the most current ADA Standards for accessible routes within multi-story buildings and facilities
- Assistive Technology Industry Association
-
Planning and Designing Outdoor Recreation Facilities for Horses
"Equestrian Design Guidebook for Trails, Trailheads, and Campgrounds," a comprehensive technical resource, details those elements of planning, design, and construction that are...
-
Inclusive Event Procedures for Emergencies
from: Grant to North Carolina Emergency Management from The North Carolina Council on Developmental Disabilities Grant to North Carolina Emergency Management The Mid-Atlantic ADA Center...
-
Wheelchair Space or Transfer Seat or Transfer Device
Commenters urged the Department to revise the requirements for wheelchair spaces and transfer seats and devices because most amusement rides are too complex to be reasonably modified or re-engineered...
-
4.10.14* Emergency Communications
If provided, emergency two-way communication systems between the elevator and a point outside the hoistway shall comply with ASME A17.1‒1990. The highest operable part of a two-way...
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
Objects are permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm)...
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
Objects are permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm)...
-
1016.7.2 Cross Slope
The cross slope shall not be steeper than 1:48. EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when...
-
Protrusions
Protrusions There may be some protrusions into wheelchair spaces on rides, but not into circulation areas, accessible routes,or load and unload areas. Where a wheelchair space is...
-
Gaps
Gaps Where wheelchair spaces are provided on amusement rides, the floors of rides must be coordinated with the floors of the load and unload areas so that when the ride is at...
-
Passing Spaces [1016.4]
Where the clear width of an ORAR is less than 60 inches, passing spaces must be provided at intervals of at least 200 feet. Passing spaces must be: A minimum space of 60...
-
Using the ORAR Exceptions [F202.3, Exception 4 and 1016, Exceptions 1, 2, and 3]
Where elements or spaces in camping and picnic facilities, viewing areas, or trailheads are altered but the circulation path to the altered element or space is not changed, the...
-
Protruding Objects [1016.9]
Objects that protrude into ORARs, passing spaces, and resting intervals can pose hazards to people who are blind or have low vision. Constructed elements, such as signs on ORARs,...
-
Boating facilities. (Section-by-Section Analysis)
Sections 206.2.10, 235.2 and 235.3 of the 2004 ADAAG require a specified number of boat slips and boarding piers at boat launch ramps to be accessible and connected to an accessible...
-
3.2.5.1 Walk-In Camping
Where walk-in camping is provided, an ORAR connecting the camp living area to the parking area shall be provided in accordance with section 2.0.
-
2.2 Surface
The surface of an ORAR shall be firm and stable. The type of surface should be appropriate to the setting and level of development.
-
2.5.1 Location
A resting interval shall be provided between each ORAR segment, in compliance with section 2.4.1. Depending on the design and location, the intersection of two ORARs may act as a...
-
2.4.2 Cross Slope
The cross slope of an ORAR shall be no more than 1:33 (3 percent). Where the surface is paved or is elevated above the natural ground, the cross slope shall not be steeper than 1:48...
-
1016.7.2 Cross Slope
The cross slope shall not be steeper than 1:48. EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when...
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
Objects are permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm)...
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
Objects are permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm)...