Where status indicators and operable parts for ICT functions are located in spaces that are frequented only by service personnel for maintenance, repair, or occasional monitoring of equipment...
Search Results "Parallel Parking Space"
Commonly Searched Documents
-
E202.4 ICT Functions Located in Maintenance or Monitoring Spaces
-
705.1.2 Dome Spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
705.1.2 Dome Spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
Turning Space [1015.4]
A turning space at least 60 inches in diameter or a T-shaped space with an arm at least 60 by 36 inches and a base at least 36 inches wide by 24 inches long (figure 29) must be provided...
-
11B-811.2 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-811.2 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-811.2 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
Wheelchair Spaces, Companion Seats, and Designated Aisle Seats: ADA Standard Section 802
Wheelchair spaces shall comply with 802.1....
-
Attachment A
Covered -- PV system covers existing accessible parking and a portion of existing standard spaces....
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
Start of Play: ADA Standard Section 1007.3.1
A clear floor or ground space 48 inches (1220 mm) minimum by 60 inches (1525 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-1007.3.1 Start of play
A clear floor or ground space 48 inches (1219 mm) minimum by 60 inches (1524 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-805.3.1 Wheelchair spaces
Where seating is provided in waiting rooms, at least 5 percent of the seating shall be wheelchair spaces complying with Section 11B-802.1....
-
Vehicle Lifting Devices
It was recommended that the guidelines address mechanical conveyances used to elevate vehicles to different levels of parking facilities....
-
1015.2 Clear Ground Space
A clear ground space shall be provided at each distinct viewing location. ...
-
1015.2 Clear Ground Space
A clear ground space shall be provided at each distinct viewing location....
-
Common Questions (Passenger Loading Zones)
Common Questions
-
11B-611.2 Clear Floor Space
11B-611.2 Clear Floor Space. A clear floor or ground space complying with Section 11B-305 positioned for parallel approach shall be provided....
-
11B-611.2 Clear Floor Space
A clear floor or ground space complying with Section 11B-305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
11B-611.2 Clear Floor Space
A clear floor or ground space complying with Section 11B-305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
1009.2.3 Clear Deck Space
1009.2.3 Clear Deck Space. On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
1015.4 Turning Space
A turning space complying with 304.3 shall be provided within viewing areas....
-
1015.4 Turning Space
A turning space complying with 304.3 shall be provided within viewing areas....