Openings providing entry to wheelchair spaces on amusement rides shall be 32 inches (813 mm) minimum clear....
Search Results "Open Captioning"
-
11B-1002.4.5 Ride entry
-
1002.4.5 Ride Entry
Openings providing entry to wheelchair spaces on amusement rides shall be 32 inches (815 mm) minimum clear....
-
Door Clear Width
Door Clear Width Open the door 90 degrees, measure from the face of the door to the edge of the door stop....
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-1002.4.5 Ride entry
Openings providing entry to wheelchair spaces on amusement rides shall be 32 inches (813 mm) minimum clear....
-
11B-1002.4.5 Ride entry
Openings providing entry to wheelchair spaces on amusement rides shall be 32 inches (813 mm) minimum clear....
-
C. The CVAA Does Not Preempt the ADA or Conflict With the ADA’s Application to This Case
There is no indication that Congress intended the CVAA and FCC to “carve captioning of streaming video programming from the ADA’s scope,” as Defendant argues. Def.’s Mem. at 15....
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
1009.4.2 Area of refuge
Exceptions: Areas of refuge are not required at the elevator in open parking garages....
-
11B-608.2.2 Standard roll-in type shower compartments
roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides with a full opening...
-
11B-608.2.2 Standard roll-in type shower compartments
roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides with a full opening...
-
606.4 Faucets
Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
606.4 Faucets
Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
407.3.5 Door Delay
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
408.3.2 Swinging Doors
Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2....
-
7e.
If the answers to questions (b) thru (d) are no, can the door be propped open to provide an accessible route on election day?...
-
4.3.11.1(4)
(4) A vestibule located immediately adjacent to an exit enclosure and constructed to the same fire-resistive standards as required for corridors and openings....
-
11B-408.3.2 Swinging doors
Swinging hoistway doors shall open and close automatically and shall comply with Sections 11B-404, 11B-407.3.2 and 11B-408.3.2....
-
11B-408.3.2 Swinging doors
Swinging hoistway doors shall open and close automatically and shall comply with Sections 11B-404, 11B-407.3.2 and 11B-408.3.2....