5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
Search Results "Folding Seat"
Commonly Searched Documents
-
5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
-
B. M301 Diagnostic Equipment Used by Patients in a Supine, Prone, or Side-lying Position and M302 Diagnostic Equipment Used by Patients in a Seated Position
final rule M301 and M302 provide the technical requirements for diagnostic equipment used in the supine, prone, or side-lying position, and diagnostic equipment used by patients in the seated...
-
Sec.36.308(a) Existing facilities
(a) Existing facilities.
-
General Requirements of Part 382
Carriers shall permit a service animal to accompany a qualified individual with a disability in any seat in which the person sits, unless the animal obstructs an aisle or other area that...
- American Standard Yorkville 1.6 gpf Right Height Elongated Pressure Assisted Toilet
- American Standard Cadet 1.6 gpf Right Height Elongated Pressure Assisted Toilet
-
Whitehall Mfg. WH2125A On-Floor ADA Compliant Bariatric Stainless Steel Toilet
Requires the Premium User plan or above. (Login or upgrade your account!)
- Figure 608.3.2 Grab Bars for Standard Roll-In Type Showers – Drawing from the U.S. Access Board
- American Standard Cadet 1.1 gpf FloWise Right Height Pressure Assisted Elongated Toilet 2467136
-
5.4.9 Interruptions Along Transfer Support Gripping for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.9 Interruptions Along Transfer Support Gripping for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
4.4.4 Clear Floor or Ground Space
Locate the clear space to provide shoulder alignment between a person sitting on the bench and a person seated in a wheelchair occupying the clear space....
-
Implication for Standards and Design
Close to 200 community dwelling adults who independently transfer have been evaluated during phases 1 and 2 combined of this multi-year study. The main difference between phase 1...
- American Standard Cadet 1.1 gpf FloWise Right Height Pressure Assisted Elongated Toilet 2467100
- American Standard Yorkville 1.1 gpf FloWise Right Height Elongated Pressure Assisted Toilet
- Caroma® USA Sydney Smart II Elongated Toilet
-
Positioning Supports Considered
panels with handholds to be provided along the sides of diagnostic equipment used by patients in a supine, prone or side-lying position, and diagnostic equipment used by patients in a seated...
-
5.4.7 Transfer Support Gripping Surface Clearance for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.7 Transfer Support Gripping Surface Clearance for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
5.4.6 Transfer Support Gripping Surface Cross Section for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.6 Transfer Support Gripping Surface Cross Section for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.2.4.2 Other Equipment
Wheelchair spaces beneath diagnostic equipment other than breast platforms shall comply with M303.2.4.2.
-
M302.2.5 Unobstructed Transfer
Each transfer side complying with M302.2.4 shall provide unobstructed access to transfer surfaces. EXCEPTIONS: 1. Obstructions no more than 3 inches (75 mm) deep shall be...
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: A running slope not steeper than 1:8 shall be permitted for ramp runs with a maximum height of 2 ½ inches...
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side with a drop off.