The standards specify the maximum pile height (1/2” measured to the backing, cushion, or pad) and texture (level or textured loop, level cut pile, or level cut/uncut pile) and require firm...
Search Results "Floor-Level Exit Sign"
Commonly Searched Documents
-
Carpet [§302.2]
-
4.30.4* Raised and Brailled Characters and Pictorial Symbol Signs
4.30.4* Raised and Brailled Characters and Pictorial Symbol Signs (Pictograms)....
-
11B-608.9 Shower floor or ground surface
11B-608.9 Shower floor or ground surface. Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
11B-813.2.9 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
Re: Husky 24" Line Generator Digital Laser Level
See Bill Hecker, AIA, Kirola vs City and County of San Francisco, Expert for DOJ, testimony with regards to Laser level lengths....
-
Determine Your Evacuation Options When Traveling
If you have difficulty using stairs, do you ask for a guest room on a lower floor?...
-
Permanent Rooms and Spaces
Section 216.2 covers designations of permanent rooms and spaces, including pictograms provided as part of such signs....
-
9.5.2(2)(d)
(d) at least one common area which a person with mobility impairments can approach, enter and exit including a minimum clear door width of 32 in (815 mm)....
-
11B-302.2 Carpet
Carpet or carpet tile shall have a level loop, textured loop, level cut pile, or level cut/uncut pile texture. Pile height shall be ½ inch (12.7 mm) maximum....
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Scooter
This data depicts the amount of clear floor area required by persons using wheeled mobility devices when performing a forward or side reach to a target location (e.g., reaching to a...
-
Voting Areas
In winter months or during the rainy season, election officials may use cardboard, plastic floor coverings, tarps, or mats to cover the floor....
-
11B-408.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Sections 11B-302 and 11B-303....
-
11B-408.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Sections 11B-302 and 11B-303....
-
11B-408.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Sections 11B-302 and 11B-303....
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and...
-
5.1.6 Clear Floor or Ground Space
A clear floor or ground space at least 36 inches (915 mm) by 48 inches (1220 mm) shall be provided parallel at the elevated entrance to the camp shelter....
-
1009.4 Elevators
Areas of refuge are not required for elevators accessed from a refuge area in conjunction with a horizontal exit....
-
Error/Omission: The door to the toilet room swings into the required clear floor space at accessible fixtures, controls, and dispensers.
For example, if a person using a wheelchair is positioned in the clear floor space at the paper towel dispenser and that clear floor space overlaps the space needed to swing the door open...
-
502.4 Floor or Ground Surfaces
Access aisles shall be at the same level as the parking spaces they serve. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted. ...
- PEMKO 7" Half Saddle/Offset Saddle Threshold No. 2727
- PEMKO 5 1/2" Half Saddle/Offset Saddle Threshold No. 158