Self-service storage spaces complying with Table 225.3 shall not be required to be dispersed among buildings in a multi-building facility....
Search Results "Building"
Commonly Searched Documents
-
225.3.1 Dispersion
-
Entrance
One commenter requested clarification on whether "entrance" refers to an entry door to a dwelling unit, or an entry door to the building. Response....
-
4.6.2 LOCATION
Parking spaces for disabled people and accessible passenger loading zones that serve a particular building shall be the spaces or zones located closest to the nearest accessible entrance...
-
Exception 7
placement of switches and receptacles, cosmetic work that does not affect items regulated by this code, such as painting, equipment not considered to be a part of the architecture of the building...
-
CHAPTER 10 MEANS OF EGRESS
ETA Editor's Note Sections from California Building Code Chapter 10 not adopted by Division of the State Architect - Access Compliance (DSA-AC) omitted....
-
CHAPTER 9 FIRE PROTECTION SYSTEMS
ETA Editor's Note Sections from California Building Code Chapter 9 not adopted by Division of the State Architect - Access Compliance (DSA-AC) omitted....
-
11B-809.5.1.1 Alarm appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with Chapter 9, Section 907.5.2.3.3 _|Visible alarms;...
-
CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
ETA Editor's Note Sections from California Building Code Chapter 4 not adopted by Division of the State Architect - Access Compliance (DSA-AC) omitted....
-
11B-233.3.1.2.3 Ground floors above grade
ETA Editor's Note This section of the 2019 California Building Code was amended by the Division of the State Architect....
-
11B-216.8 Toilet rooms and bathing rooms
Existing buildings that have been remodeled to provide specific toilet rooms or bathing rooms for public use that comply with these building standards shall have the location of and the...
-
206.7.5 Existing Site Constraints
While the site constraint must reflect exterior conditions, the lift can be installed in the interior of a building....
-
[A] ALTERATION
[DSA-AC] A change, addition or modification in construction, change in occupancy or use, or structural repair to an existing building or facility....
-
11B-217.4 TTYs
Separate requirements are provided based on the number of public pay telephones provided at a bank of telephones, within a floor, a building, or on a site....
-
11B-206.7.5 Existing site constraints
While the site constraint must reflect exterior conditions, the lift can be installed in the interior of a building....
-
Scoping [4.1.2(6), 4.1.3(11)]
Scoping [4.1.2(6), 4.1.3(11)] Building codes, plumbing codes, or health regulations in force locally define the number and type of toilet/bathing facilities (and fixtures) required in...
-
11B-206.7.5 Existing site constraints
While the site constraint must reflect exterior conditions, the lift can be installed in the interior of a building....
-
[A] ALTERATION
[DSA-AC] A change, addition or modification in construction, change in occupancy or use, or structural repair to an existing building or facility....
-
11B-206.7.5 Existing site constraints
While the site constraint must reflect exterior conditions, the lift can be installed in the interior of a building....
-
225.3.1 Dispersion
Self-service storage spaces complying with Table 225.3 shall not be required to be dispersed among buildings in a multi-building facility....
-
11B-225.3.1 Dispersion
Self-service storage spaces complying with Table 11B-225.3 shall not be required to be dispersed among buildings in a multi-building facility. ...
-
1150A.2
ETA Editor's Note Section 1150A.2 from California Building Code Chapter 11A, not adopted by Division of the State Architect - Access Compliance (DSA-AC), omitted. ...
-
CHAPTER 31B [DPH] PUBLIC SCHOOLS
ETA Editor's Note This Pocket Guide contains only the excerpts from California Building Code Chapter 31B that are adopted by Division of the State Architect - Access Compliance (DSA-AC...
-
CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
ETA Editor's Note This Pocket Guide contains only the excerpts from California Building Code Chapter 30 that are adopted by Division of the State Architect - Access Compliance (DSA-AC...
-
11B-225.3.1 Dispersion
Self-service storage spaces complying with Table 11B-225.3 shall not be required to be dispersed among buildings in a multi-building facility. ...