For example, unlike the ADA guidelines, the ANSI standards require an additional vertical grab bar at water closets, transfer shower stalls, and tubs....
Search Results "Vertical Rod"
-
Model Building Codes and Industry Standards
-
§ 38.175(a)
Vertical alignment may be accomplished by car air suspension or other suitable means of meeting the requirement....
-
1118B.3
Changes in level up to 1/4 inch (6.4 mm) may be vertical and without edge treatment [see Figure 11B-5E(c)]....
- Hollaender ADA Handrail Systems: Grabrail (ADA Rail)
- Landscape Forms Inc. FGP Trash Receptacle
- Kawneer North America AA™250/425 Thermal Entrances
- Willoughby Industries ETW-1490-FM-HC Floor Mounted Blowout Series Water Closet
- Florestone 35-62H Barrier-Free Shower
- 1100KG BT Digital Platform Scale Extra Wide Handrails and Built-in Pelstar® Wireless Technology
-
M301.4.1 Clearance in Base (Section-by-Section Analysis)
Three commenters (two manufacturers and one medical association) raised concerns with the six-inch vertical clearance measured from the floor requirement....
-
Boat Slips: ADA Standard Section 1003.2.1
The vertical distance is 10 feet (3050 mm) between the elevation where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level....
-
11B-1003.2.1 Boat slips
The vertical distance is 10 feet (3050 mm) between the elevation where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level....
-
11B-206.2.8 Employee work areas
However, passenger elevators used for vertical transportation between stories are not considered "work area equipment" as defined in Chapter 2, Section 202. ◼...
-
11B-206.2.8 Employee work areas
However, passenger elevators used for vertical transportation between stories are not considered "work area equipment" as defined in Chapter 2, Section 202. ◼...
-
11B-1003.2.1 Boat slips
The vertical distance is 10 feet (3050 mm) between the elevation where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level....
-
11B-805 Medical care and long-term care facilities
Touch screen units shall be allowed to be vertically mounted with the centerline of the display screen no more than 52 inches above the floor in compliance with Section 11B-707.7.1.1....
-
Resting Intervals [1016.8]
The vertical alignment of the ORAR, turning space, and resting interval must be nominally planar (i.e., as flat as possible) so that all the wheels of a mobility device touch the ground...
-
Dune Crossings [1018.10]
The technical requirements for dune crossings do not address the vertical pickets provided in some handrail designs....
-
1. Typical Issues for Individuals Who Use Wheelchairs, Scooters, or other Mobility Devices
Ramps with a vertical rise of more than 6 inches must have handrails on both sides....
-
Transit Stops (R308.1) (Section-by-Section Analysis)
Boarding platforms at transit stops must be positioned to coordinate with vehicles to minimize the vertical and horizontal gaps....
-
1010.1.7 Thresholds
Raised thresholds and floor level changes greater than ¼ inch (6.4 mm) at doorways shall be beveled with a slope not greater than one unit vertical in two units horizontal (50-percent slope...
- Harmar IL500 Sierra Incline Platform Lift
-
1002.6 Transfer Devices for Use with Amusement Rides
Where a series of transfers are required to reach the amusement ride seat, each vertical transfer should not exceed 8 inches (205 mm)....
-
11B-1002.6 Transfer devices for use with amusement rides
Where a series of transfers are required to reach the amusement ride seat, each vertical transfer should not exceed 8 inches (205 mm). ...