(4) Ramp barriers. Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off.
Search Results "Vehicle Floor Coordination"
Commonly Searched Documents
-
§ 38.83(c)(4) Ramp barriers
-
§ 38.159(b)(1) Design load
(1) Design load. The design load of the lift shall be at least 600 pounds (2665 N). Working parts, such as cables, pulleys, and shafts, which can be expected to wear, and upon which...
-
11B-228.3.1.1 Existing facilities
Where new EVCS are added to a facility with existing EVCS, the requirements of Section 11B-812 shall apply only to the new EVCS installed. Alterations to existing EVCS shall comply...
-
11B-812.5.1 Accessible route to building or facility
EVCS complying with Section 11B-812 that serve a particular building or facility shall be located on an accessible route to an entrance complying with Section 11B-206.4. Where EVCS...
-
11B-228.3.1.1 Existing facilities
Where new EVCS are added to a facility with existing EVCS, the requirements of Section 11B-812 shall apply only to the new EVCS installed. Alterations to existing EVCS shall comply...
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
11B-603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
11B-603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
4.33.2* Size of Wheelchair Locations
Each wheelchair location shall provide minimum clear ground or floor spaces as shown in Fig. 46....
-
4.1.3(3)
(3) Ground and floor surfaces along accessible routes and in accessible rooms and spaces shall comply with 4.5....
-
4.1.2(3)
(3) Ground and floor surfaces along accessible routes and in accessible rooms and spaces shall comply with 4.5....
-
4.33.2* SIZE OF WHEELCHAIR LOCATIONS
Each wheelchair location shall provide minimum clear ground or floor spaces as shown in Fig. 46....
-
305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element....
-
11B-603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
407.2.3.1 Floor Designation
Floor designations complying with 703.2 and 703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum....
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum....
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum....