5.4.6 Transfer Support Gripping Surface Cross Section for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
Search Results "Stadium-Style Seating"
Commonly Searched Documents
-
5.4.6 Transfer Support Gripping Surface Cross Section for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.2.4.2 Other Equipment
Wheelchair spaces beneath diagnostic equipment other than breast platforms shall comply with M303.2.4.2.
-
M302.2.5 Unobstructed Transfer
Each transfer side complying with M302.2.4 shall provide unobstructed access to transfer surfaces. EXCEPTIONS: 1. Obstructions no more than 3 inches (75 mm) deep shall be...
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: A running slope not steeper than 1:8 shall be permitted for ramp runs with a maximum height of 2 ½ inches...
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side with a drop off.
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on both sides.
-
M303.2.6 Edge Protection (Section-by-Section Analysis)
The MDE NPRM proposed edge protection on the ramps leading up to the raised platform (proposed M303.3.3.4), but did not require edge protection on the raised platforms themselves....
-
M302.2.5 Unobstructed Transfer (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed that each transfer side provide unobstructed access to the transfer surface, with an exception to permit temporary obstructions as long as...
-
5.8.1.1 Clear Platform Size Recommendation
5.8.1.1 Clear Platform Size Recommendation The Committee recommends a platform size with a minimum clear width of 32 inches and a minimum clear length of 40 inches. Rationale...
-
5.8.1.1 Clear Platform Size
5.8.1.1 Clear Platform Size. The platform should be a minimum clear width of 32-inches and a minimum clear length of 40-inches.
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on each side.
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12.
-
§ 38.55(b)
(b) Characters on signs required by paragraph (a) of this section shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10, with...
-
M303.2.6 Edge Protection
Where wheelchair spaces are provided on a platform raised more than 1 ½ inches (38 mm) in height, edge protection 2 inches (51 mm) high minimum measured from the surface of the...
- Caroma® USA Sydney Smart II Elongated Toilet
-
Chapter 1: Background
Current standards have criteria only related to seat height and clear floor space for wheelchair users (2)....
-
226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with 902....
-
Amusement Rides
Word Fillable Form (0.8MB) Word Non-Fillable Form (0.7MB) PDF Non-Fillable Form (0.5MB)
-
Plan 5A: 13-Foot Wide Accessible Guest Room
Furnishings include a king bed and additional seating. ...
-
221.1.1 Florida Vertical Accessibility
Theaters, concert halls, and stadiums, or other large assembly areas that have stadium-style seating or tiered seating if the requirements of sections 221 and 802 are met....
-
M302.2.1 Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in a seated position of 17 inches minimum and 19 inches maximum....
-
5.4.4 Transfer Support Distance From Transfer Surface for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.4 Transfer Support Distance From Transfer Surface for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....