Doorways shall provide a clear opening of 32 inches (813 mm) minimum in power-on and power-off mode....
Search Results "Shall"
-
11B-404.3.1 Clear width
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...
-
1009.6.3 Size
Each area of refuge shall be sized to accommodate two wheelchair spaces that are not less than 30 inches by 52 inches (762 mm by 1320 mm)....
-
11B-404.3.1 Clear width
Doorways shall provide a clear opening of 32 inches (813 mm) minimum in power-on and power-off mode....
-
11B-809.9.2 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, work surface or the face of any appliance (excluding handles and controls) and the opposing cabinet, work surface,...
-
11B-703.2.7 Character spacing
Character spacing shall be measured between the two closest points of adjacent raised characters within a message, excluding word spaces....
-
1009.6.3 Size
Each area of refuge shall be sized to accommodate two wheelchair spaces that are not less than 30 inches by 52 inches (762 mm by 1320 mm)....
-
11B-207.1 General
Means of egress shall comply with Chapter 10, Section 1009 and Section 11B-207. [2010 ADA Standards] 207.1 General....
-
Recreational Boating Facilities: ADA Standard Section 206.2.10
Section 206.2.10 covers scoping requirements in the most current ADA Standards for accessible routes to recreational boating facilities
-
Coat Hooks and Shelves: ADA Standard Section 803.5
Coat hooks provided within the room shall be located within one of the reach ranges specified in 308....
-
Residential Dwelling Units with Mobility Features: ADA Standard Section 233.3.1.1
Section 233.3.1.1 covers scoping requirements in the current ADA Standards for residential dwelling units with mobility features.
-
11B-703.1 General
Signs shall comply with Section 11B-703....
-
11B-409.3 Elevator doors
Hoistway doors, car doors, and car gates shall comply with Sections 11B-409.3 and 11B-404....
-
11B-206.2.9 Amusement rides
Amusement rides required to comply with Section 11B-234 shall provide accessible routes in accordance with Section 11B-206.2.9....
-
11B-809.8.4 Door signal devices
Every primary entrance to a residential dwelling unit with adaptable features shall be provided with a door buzzer, bell, chime or equivalent....
-
11B-807.3.1 Alarms
Where audible emergency alarm systems are provided to serve the occupants of cells, visible alarms complying with Section 11B-702 shall be provided....
-
11B-605.5.1 Urinal location
Urinals in compartments shall have the centerline of the urinal located 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from the side wall or partition....
-
11B-206.2.9 Amusement rides
Amusement rides required to comply with Section 11B-234 shall provide accessible routes in accordance with Section 11B-206.2.9....
-
11B-409.3 Elevator doors
Hoistway doors, car doors, and car gates shall comply with Sections 11B-409.3 and 11B-404....
-
11B-703.1 General
Signs shall comply with Section 11B-703....
-
11B-807.3.1 Alarms
Where audible emergency alarm systems are provided to serve the occupants of cells, visible alarms complying with Section 11B-702 shall be provided....
-
11B-809.8.4 Door signal devices
Every primary entrance to a residential dwelling unit with adaptable features shall be provided with a door buzzer, bell, chime or equivalent....
-
11B-605.5.1 Urinal location
Urinals in compartments shall have the centerline of the urinal located 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from the side wall or partition....
-
Security Barriers: ADA Standard Section 206.8
Section 206.8 covers scoping requirements in the most current ADA Standards for accessible routes through security barriers.