The fire-resistance-rated exterior wall construction shall extend horizontally 10 feet (3048 mm) beyond the landing on either side of the landing or equivalent fire-resistance-rated construction...
Search Results "Horizontal Position"
-
1009.7.2 Separation
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
4.6.3 Eyepiece
The eyepiece for the telescope or periscope that is usable from a seated position for viewing each point of interest shall be positioned 43 inches (1090 mm) minimum and 51 inches (1295 mm...
-
Medical Diagnostic Equipment Accessibility Standards Sub Committee Recommendations Stretcher Final Report
Specifically, Section M301, Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position....
- Pilot Rock CN-AMQ Amherst Collection Square Ash Receptacles
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
1131A.1 Changes in level not exceeding ½ inch
When changes in level do occur, they shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
7(2)(b)(v)
(v) Vanities and lavatories are installed with the centerline of the fixture a minimum of 1'3" horizontally from an adjoining wall or fixture....
-
11B-1008.3.2.3 Transfer supports
Some examples of supports include a rope loop, a loop type handle, a slot in the edge of a flat horizontal or vertical member, poles or bars, or D rings on the corner posts....
-
Cross Slope
This may be expressed as the percentage of change in elevation or as a ratio of vertical distance to horizontal distance....
-
11B-1008.3.2.3 Transfer supports
Some examples of supports include a rope loop, a loop type handle, a slot in the edge of a flat horizontal or vertical member, poles or bars, or D rings on the corner posts....
-
§ 38.93(d)(3) Exception
Where platform set-backs do not allow the horizontal gap or vertical alignment specified in paragraph (d)(1) or (d)(2) of this section, car, platform or portable lifts complying with §38.95...
-
§ 38.95(b)(7) Platform gaps
When the lift is at car floor height with the inner barrier down (if applicable) or retracted, gaps between the forward lift platform edge and car floor shall not exceed 1/2 inch horizontally...
-
§ 38.125(b)(7) Platform gaps
When the lift is at car floor height with the inner barrier (if applicable) down or retracted, gaps between the forward lift platform edge and car floor shall not exceed 1/2 inch horizontally...
-
11B-1008.3.2.3 Transfer supports
Some examples of supports include a rope loop, a loop type handle, a slot in the edge of a flat horizontal or vertical member, poles or bars, or D rings on the corner posts. ◼...
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
206.2.9.1 Load and Unload Areas
Where load and unload areas have more than one loading or unloading position, at least one loading and unloading position shall be on an accessible route....
-
11B-904.4.1 Parallel approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a parallel approach adjacent to the 36 inch (914 mm) minimum length of counter....
-
11B-604.4 Seats
Seats shall not be sprung to return to a lifted position. Seats shall be 2 inches (51 mm) high maximum. [2010 ADA Standards] 604.4 Seats....
-
11B-604.4 Seats
Seats shall not be sprung to return to a lifted position. Seats shall be 2 inches (51 mm) high maximum. [2010 ADA Standards] 604.4 Seats....
-
11B-904.4.1 Parallel approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a parallel approach adjacent to the 36 inch (914 mm) minimum length of counter....
-
11B-703.4.2 Location
that a clear floor space of 18 inches (457 mm) minimum by 18 inches (457 mm) minimum, centered on the tactile characters, is provided beyond the arc of any door swing between the closed position...
-
11B-703.4.2 Location
that a clear floor space of 18 inches (457 mm) minimum by 18 inches (457 mm) minimum, centered on the tactile characters, is provided beyond the arc of any door swing between the closed position...
-
1009.2.6 Footrests and Armrests
If provided, the armrest positioned opposite the water shall be removable or shall fold clear of the seat when the seat is in the raised (load) position....