At least one means of support for transferring shall be provided.
Search Results "Elevator Hall Call Button"
Commonly Searched Documents
-
11B-1008.3.1.4 Transfer supports
-
11B-407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum.
-
11B-407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses.
-
11B-409.4.3 Platform to hoistway clearance
The clearance between the car platform and the edge of any landing sill shall be 1½ inch (38 mm) maximum.
-
11B-1008.3.2.3 Transfer supports
At least one means of support for transferring shall be provided. Advisory 11B-1008.3.2.3 Transfer supports. Transfer supports are required on transfer platforms and transfer...
-
11B-409.4.7.2 Operable parts
The telephone and emergency signaling device shall comply with Sections 11B-309.3 and 11B-309.4.
-
11B-1008.3.1.3 Transfer space
A transfer space complying with Sections 11B-305.2 and 11B-305.3 shall be provided adjacent to the transfer platform. The 48 inch (1219 mm) long minimum dimension of the transfer...
-
11B-407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
Section 36.404 Alterations: Elevator Exemption (Section-By-Section Analysis and Response to Comments)
Section 36.404 Alterations: Elevator Exemption (Section-By-Section Analysis and Response to Comments) Section 36.404 implements the elevator exemption in section 303(b) of the Act as...
-
408 Limited-Use/Limited-Application Elevators
[See subsections ...]
-
408 Limited-Use/Limited-Application Elevators
[See subsections ...]
- GameTime Rock N Raft Play Component
-
Additional Number and Types: ADA Standard Section 240.2.1.2
Section 240.2.1.2 covers scoping requirements in the current ADA Standards for additional number and types of ground level play components.
-
11B-240.2.1.2 Additional number and types
Where elevated play components are provided, ground level play components shall be provided in accordance with Table 11B-240.2.1.2 and shall comply with Section 11B-1008.4....
-
5. Is a talk tube where two children talk to each other simultaneously considered one or two play components? If one end of the talk tube is at ground level and the other is on an elevated deck, is it considered a ground level or elevated play component?
If one end of the talk tube is at ground level and the other is on an elevated deck, is it considered a ground level or elevated play component?...
-
Machinery Spaces: ADA Standard Section 203.5
Section 203.5 covers scoping requirements of general exceptions for machinery spaces in the most current ADA Standards.
-
11B-203.5 Machinery spaces
Machinery spaces include, but are not limited to, elevator pits or elevator penthouses; mechanical, electrical or communications equipment rooms; piping or equipment catwalks; water or sewage...
-
A. General Requirements for Telephone Emergency Service Providers
Direct access means that PSAPs can directly receive TTY calls without relying on an outside relay service or third-party services....
- Kompan, Inc. Elements Play Structures Ridge ELE500003
-
409.4.2 Floor Surfaces
Floor surfaces in elevator cars shall comply with 302 and 303....
-
409.4.2 Floor Surfaces
Floor surfaces in elevator cars shall comply with 302 and 303....
-
11B-707.6.1 Input controls
At least one tactilely discernible input control shall be provided for each function. Where provided, key surfaces not on active areas of display screens, shall be raised above...
-
707.6.1 Input Controls
At least one tactilely discernible input control shall be provided for each function. Where provided, key surfaces not on active areas of display screens, shall be raised above...
-
Issue 10: Braille (right side up?)
Issue 10: Braille (right side up?) Where the APS device includes the street name in Braille, care must be taken to install the signs in the correct location and...