Acceptable door opening and inside dimensions shall be as shown in Fig. 22....
Search Results "Door Pull"
-
4.10.9 FLOOR PLAN OF ELEVATOR CARS
-
Toilet Rooms South (Briefing Theater)
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). kk....
-
Door Swing [§304.4] and Other Space Requirements
Door Swing [§304.4] and Other Space Requirements Doors can swing into the turning space....
-
Multiple Usable Entrances
However, the requirements for usable doors and an accessible route to exterior spaces such as balconies and decks does respond to this concern....
- Don-Jo Mfg., Inc. 5" Hospital Latch 4550
-
11B-411.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-411.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-411.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
- Don-Jo Mfg., Inc. 2-3/4" Hospital Latch 4500
- Norton Surface Mounted 5600 Hands-Free Door Operation Kits
- Access Board: Door Opening Force
-
Error/Omission: The door to the toilet room swings into the required clear floor space at accessible fixtures, controls, and dispensers.
Error/Omission: The door to the toilet room swings into the required clear floor space at accessible fixtures, controls, and dispensers....
-
Architect
The 4040XP provides adjustments for Position 1-6, has a range of interior and exterior door sizes it can work on....
-
Measuring Door Openings
To measure the clear opening of a standard hinged door, open the door to 90 degrees....
-
4.34.5.1 DOORS
Doors shall not swing into the clear floor space required for any fixture....
-
9.4 Other Sleeping Rooms and Suites
Doors and doorways designed to allow passage into and within all sleeping units or other covered units shall comply with 4.13.5....
-
1010.1.5 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....
-
Entrance
One commenter requested clarification on whether "entrance" refers to an entry door to a dwelling unit, or an entry door to the building. Response....
-
Maneuvering Clearances [§404.2.4]
Maneuvering Clearances [§404.2.4] Required maneuvering clearances provide space for opening and proceeding through doors, doorways, and gates using wheelchairs and other mobility aids...
-
9.2.2(3)
(3) Doors and doorways designed to allow passage into and within all sleeping rooms, suites or other covered units shall comply with 4.13....
-
Q4.) Are conditions like door closers that require force in excess of the maximum allowed by the standards considered true tolerances or are they simply non-compliance with the maintenance requirements of 35.133 or 36.211?
A4.) In our opinion, the plain language of the term “Construction and Manufacturing Tolerances” does not include adjustable conditions that can meet the detailed requirements when...
-
Problem Four (Entrance)
Problem Four: The entrance door has a door knob and/or latch that requires tight pinching and twisting and is not accessible....