At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
Search Results "Compartment Depth"
Commonly Searched Documents
-
505.10.3 Bottom Extension at Stairs
-
M302.2 Transfer Surface
Transfer Surface M302.2.3 Transfer Sides Proposed requirement: The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth...
-
M303.2.4 Knee and Toe Clearance
The depth of the wheelchair space shall include knee and toe clearance of 17 inches (430 mm) minimum and 25 inches (635 mm) maximum....
-
4.4 Knee and Toe Clearances
Knee Clearance Height (KCH) 685 640-650 680 700 Knee Clearance Depth (KCDL) 280...
-
Clear space
To calculate the space, three points were recorded for transfers to and from the platform: a point to the right of center, a point to the left of center, and a depth value (Figure 2)....
-
5.4.2 Transfer Support Length for M301 and M302
The transfer support would extend horizontally the entire depth of the transfer surface and would be 15 inches minimum in length....
-
C. M303 Diagnostic Equipment Used by Patients Seated in a Wheelchair
significant changes to accommodate the unique challenges of mammography equipment; one significant change to the ramped running slope requirement; and a final significant change to the width and depth...
-
Transfer Surface Size – M301.2.2 Supine, Prone, or Side-Lying Position
Transfer Surface Size – M301.2.2 Supine, Prone, or Side-Lying Position The issues were discussed and decided in the full committee meeting as follows: depth of 17 inches minimum and width...
-
4.34.6.5(7)
The knee space shall have a clear width of 30 in (760 mm) and a clear depth of 19 in (485 mm)....
-
Turning Space: ADA Standard Section 809.2.2
EXCEPTION: Turning space shall not be required in exterior spaces 30 inches (760 mm) maximum in depth or width. Advisory 809.2.2 Turning Space....
-
If Service Animal Cannot be Accommodated at Assigned Seat
Switching seats in the same class of service must be explored as an alternative before requiring that the service animal travel in the cargo compartment. [Sec. 382.37(c)]...
- UMEA Waste Receptacle
-
505.10.3 Bottom Extension at Stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
Seating [4.32.2] and Knee Clearance [4.32.3]
Seating [4.32.2] and Knee Clearance [4.32.3] Knee space at least 27 inches high is required for a depth of 19 inches....
-
4.34.6.4(4)
The knee space shall have a minimum clear width of 30 in (760 mm) and a minimum clear depth of 19 in (485 mm)....
-
5.4.1.2 Transfer and Positioning Support Location Recommendations for Imaging Equipment with Transfer Surfaces
of less than or equal to 24 inches and positioning supports for transfer depths greater than 24 inches....
-
Shower Spray Controls
In accessible bathtubs and shower compartments, sections 607.6 and 608.6 of the 2010 Standards require shower spray controls to have an on/off control and to deliver water that is 120°F...
-
§ 38.113(b) Passageway
by paragraph (a) of this section shall permit access by persons using mobility aids and shall have an unobstructed passageway at least 32 inches wide leading to an accessible sleeping compartment...
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
407.8.3.2.1 Operable Part Height for ICT with Obstructed Forward Reach
Table 407.8.3.2.1 Operable Part Height for ICT with Obstructed Forward Reach Reach Depth Operable Part Height Less than 20 inches (510 mm) 48 inches...
-
Clear Floor Space [4.27.2]
controls, dispensers, receptacles, and other operable equipment as specified in 4.2; those recessed within niches or alcoves may require additional maneuvering space depending on the recess depth...
-
4.21.3 SEAT
The seat shall be mounted 17 in to 19 in (430 mm to 485 mm) from the bathroom floor and shall extend the full depth of the stall. The seat shall be on the wall opposite the controls....
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...