M303.3 Entry
Where there is a change in level at the entry to wheelchair spaces, the change in level shall comply with M303.3.
-
M303.2.4.2.1 Depth
Wheelchair spaces shall include knee and toe clearance 17 inches (430 mm) deep minimum and 25 inches (635 mm) deep maximum.
-
M303.2.4.2.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum measured from the toe end of the...
-
11B-221.2.1.2 Luxury boxes, club boxes, and suites in arenas, stadiums, and grandstands
In each luxury box, club box, and suite within arenas, stadiums, and grandstands, wheelchair spaces complying with Section 11B-802.1 shall be provided in accordance with Table...
-
M303.3 Entry (Section-by-Section Analysis)
This is an introductory section.
-
5.8.1 Wheelchair Spaces on Raised Platforms
5.8.1 Wheelchair Spaces on Raised Platforms.
-
M303.3 Entry
Where there is a change in level at the entry to a wheelchair space, the change in level shall comply with M303.3.
-
Doors in Series and Gates in Series: ADA Standard Section 404.2.6
Section 404.2.6 covers the current ADA Standards for doors in series and gates in series.
-
§ 35.151(g) Assembly areas
(g) Assembly areas. Assembly areas subject to the proposed standards shall comply with the provisions applicable to assembly areas, including, but not limited to, sections 221 and...
-
§ 35.151(g) Assembly areas.
(g) Assembly areas. Assembly areas subject to this section shall comply with the provisions of the 2010 Standards applicable to assembly areas, including, but not limited to,...
-
5.4.3 Transfer Support Height for M301 and M302
would be an appropriate height for transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated...
-
Height
would be an appropriate height for transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated...
-
Willoughby Industries ETW-1445-BS-HC ADA Compliant Toilet for 45-degree Chase Wall
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Willoughby Industries ETW-1490-FM-BS-HC Floor Mounted Blowout Series Water Closet
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Willoughby Industries ETW-1490-FM-TS-HC Floor Mounted Blowout Series Water Closet
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Neo-Metro Contour Commercial Toilet 8955 Series Model
Requires the Premium User plan or above. (Login or upgrade your account!)
-
a. Knee and Toe Clearance
The requirements are intended to ensure that there is adequate space for a patient seated in a wheelchair to position underneath the equipment and align themselves against the breast platform...
- Caroma® USA Somerton Smart 270 Easy Height Elongated Toilet
- Caroma® USA Sydney Low Profile 270 Easy Height Elongated Toilet
-
Section 36.406(f) Assembly Areas (Section-by-Section Analysis)
These platforms cover groups of conventional seats and are used to provide groups of wheelchair seats and companion seats....
-
Cross Section of Gripping Surfaces
appropriate for the gripping surfaces of transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated...
-
5.8.2.4 Unobstructed Floor Space Recommendation
In order to image as much of the breast as possible, patients cannot be seated in the “natural” sitting position....