Safety The Segway must be operated in a manner that does not compromise the safety of the user, the building occupants or the building infrastructure. ...
Search Results "Vacated Building"
-
Safety
-
Who Will Provide the Assistance?
Anyone in the Office or Building People with limited mobility who are able to go up and down stairs easily but have trouble operating door locks, latches, and other devices due to limitations...
-
VII. New Construction and Alterations
When a public entity undertakes alterations to an existing building, it must also ensure that the altered portions are accessible....
-
State and Local Access Codes
Building design and construction, including safety and accessibility, is largely regulated and enforced by states and local jurisdictions....
-
F206.4.7 Restricted Entrances
Where restricted entrances are provided to a building or facility, at least one restricted entrance to the building or facility shall comply with 404....
-
206.4.7 Restricted Entrances
Where restricted entrances are provided to a building or facility, at least one restricted entrance to the building or facility shall comply with 404....
-
General: ADA Standard Section 208.3.1
Section 208.3.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for parking space locations.
-
11B-504.5 Nosings
Exception: In existing buildings there is no requirement to retroactively alter existing nosing projections of 1½ inches (38 mm) which were constructed in compliance with the building code...
-
11B-206.4 Entrances
Where an alteration includes alterations to an entrance, and the building or facility has another entrance complying with 404 that is on an accessible route, the altered entrance shall not...
-
11B-504.5 Nosings
Exception: In existing buildings there is no requirement to retroactively alter existing nosing projections of 1½ inches (38 mm) which were constructed in compliance with the building code...
-
PATH OF TRAVEL
[DSA-AC] An identifiable accessible route within an existing site, building or facility by means of which a particular area may be approached, entered and exited, and which connects a particular...
-
PATH OF TRAVEL
[DSA-AC] An identifiable accessible route within an existing site, building or facility by means of which a particular area may be approached, entered and exited, and which connects a particular...
-
Sec. 469.054(b)
(b) The owner of a building or facility is responsible for paying a fee charged by the commission for performing a function under this chapter related to the building or facility....
-
1.1.7.1 Differences
In the event of any differences between these building standards and the standard reference documents, the text of these building standards shall govern....
-
EGRESS, MEANS OF
An accessible route of exit that meets all applicable code specifications of the regulatory building agency having jurisdiction over the building or facility....
-
11B-206.4.3 Entrances from tunnels or elevated walkways
Where direct access is provided for pedestrians from a pedestrian tunnel or elevated walkway to a building or facility, all entrances to the building or facility from each tunnel or walkway...
-
1. LEGAL ISSUES
Attorney General’s office, developing guidelines for construction tolerances "…unnecessarily encourages contractors and others to deviate from the access regulations found in the California Building...
-
4.1.5(1) ENTRANCES
If a new addition to a building or facility does not have an entrance, then at least one entrance in the existing building or facility shall comply with 4.1.4, Entrances....
-
ENTRANCE
Any access point to a building or portion of building or facility used for the purpose of entering....
-
Technically Infeasible
With respect to an alteration of a building or a facility, something that has little likelihood of being accomplished because existing structural conditions would require removing or altering...
-
1009.7.4 Stairways
Exception: The minimum clear width of 48 inches (1220 mm) between handrails is not required at stairways serving buildings equipped throughout with an automatic sprinkler system installed...
-
1009.7.4 Stairways
Exception: The minimum clear width of 48 inches (1219 mm) between handrails is not required at stairways serving buildings equipped throughout with an automatic sprinkler system installed...
-
11B-902.2.1 Overlap
ETA Editor's Note: From DSA's "Summary of New and Amended 2025 California Building Code (CBC) Regulations for Accessibility in the Triennial Code Cycle": "Section 11B-902.2 has been amended...
-
2. a. Accessible route into and throughout the facility
Accessible route into and throughout the facility - The following is a 4-point guideline for ensuring equal access from the parking lot, outdoor walkways, entrances and exists of the buildings...