A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADAS] 805.3 Clear Floor or Ground Space....
Search Results "Push Side"
Commonly Searched Documents
-
11B-805.2.2 Beds
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADA Standards] 805.3 Clear Floor or Ground Space....
- Oasis Barrier-Free Universal Split-Level VersaCooler II P8ACSL
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
American Dryer, Inc Advantage™ AD Automatic Hand Dryer - Right Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
American Dryer, Inc Global® GX Hand Dryer Series - Right Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley 3-Station Express Deck Lavatory System EXD-3N WH Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley Grab Bars 1 1/2" with Concealed Mounting 812 136 Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley Grab Bars 1 1/4" with Concealed Mounting 832 136 Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley Grab Bars 1 1/2" with Concealed Mounting 812 124 Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley Low Capacity Towel Dispenser & 2 Gallon Waste Receptacle 2291 Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Kohler C3® 125 Elongated Bidet Toilet Seat With Side Controls and Tank Heater
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley Recessed Stainless Steel Stacking Rolls Toilet Tissue Dispenser 5412 Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Is front-in only or angled parking prohibited for accessible parking spaces?
However, where van spaces are angled, the Standards require the access aisle to be located on the passenger side which is the side where vehicle ramps and lifts are typically deployed....
-
604.8.2.3 Grab Bars
A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment....
-
604.8.2.3 Grab Bars
A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment....
-
Transfer Type Shower Compartments: ADA Standard Section 608.5.1
Section 608.5.1 covers the current ADA Standards for controls in transfer type shower compartments.
-
11B-602.3 Operable parts
The flow of water shall be activated by a manually operated system that is front mounted or side mounted and located within 6 inches (152 mm) of the front edge of the fountain or an automatic...
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-608.5.1 Transfer type shower compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm...
-
Manual Wheelchairs
Users can propel themselves using push rims attached to the rear wheels. Braking is accomplished by resisting wheel movement with the hands or arms....
-
404.2.9 Door and Gate Opening Force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2....