TABLE 11B-224.2 GUEST ROOMS WITH MOBILITY FEATURES TOTAL NUMBER OF GUEST ROOMS PROVIDED MINIMUM NUMBER OF REQUIRED ROOMS WITHOUT ROLL-IN SHOWERS1 MINIMUM...
Search Results "Patient Toilet Room"
-
11B-224.2 Guest rooms with mobility features
-
5.2.1.2 Transfer Surface Depth
The transfer surface should be 17 inches deep minimum for all equipment used by patients in a supine, side-lying, or prone position with the exception of imaging equipment....
-
M302.4.2 Clearance Around Base
The base of the diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of...
-
5.4.2.1 Transfer Support Length for Stretchers
5.4.2.1 Transfer Support Length for Stretchers. Transfer supports on stretchers should be a minimum of 15 inches long.
-
5.3.2.1 Transfer Sides for Stretchers
5.3.2.1 Transfer Sides for Stretchers. The transfer surface shall be located to provide the ability to transfer from a mobility device onto both long sides of the surface.
-
M302.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...
-
M305.4 Leg Supports (Section-by-Section Analysis)
The MDE NPRM proposed that where stirrups are provided, they must provide a method to support, position, and secure the patients legs....
-
11B-803.5 Coat hooks and shelves
Coat hooks provided within the room shall be located within one of the reach ranges specified in Section 11B-308....
-
11B-803.5 Coat hooks and shelves
Coat hooks provided within the room shall be located within one of the reach ranges specified in Section 11B-308....
-
11B-203.2 Construction sites
Portable toilet units provided for use exclusively by construction personnel on a construction site shall not be required to comply with Section 11B-213 or to be on an accessible route....
-
11B-203.2 Construction sites
Portable toilet units provided for use exclusively by construction personnel on a construction site shall not be required to comply with Section 11B-213 or to be on an accessible route....
-
11B-803.5 Coat hooks and shelves
Coat hooks provided within the room shall be located within one of the reach ranges specified in Section 11B-308....
-
Accessible Hotel Rooms (Section-By-Section Analysis and Response to Comments)
- Rather than requiring 5% of new hotel rooms to be accessible to people with mobility impairments, between 2 and 4% accessibility (depending on total number of rooms) is required....
- Bradley Diplomat Toilet Tissue Dispenser 5A20
- Bradley Diplomat Toilet Tissue Dispenser 5A00
- Bradley Diplomat Toilet Tissue Dispenser 5A10
-
F222.2 Coat Hooks and Shelves
Where coat hooks or shelves are provided in dressing, fitting or locker rooms without individual compartments, at least one of each type shall comply with 803.5....
-
222.2 Coat Hooks and Shelves
Where coat hooks or shelves are provided in dressing, fitting or locker rooms without individual compartments, at least one of each type shall comply with 803.5....
-
604 Water Closets and Toilet Compartments
[See subsections ...]
-
604 Water Closets and Toilet Compartments
[See subsections ...]
-
C. Architectural Barrier Removal (Non-seating)
Olympia shall address certain of Joe Louis Arena’s architectural barriers to access, including parking, signage, entrances, locker rooms, first aid rooms, rest rooms, restaurants,...
- Mega Jailhouse Anti-Ligature Toilet Paper Holder With Exposed Mount
-
M301.3.2 Stirrups
Where stirrups are provided, they shall provide a method of supporting, positioning, and securing the patient’s legs....
-
5.2.1.1 Transfer Surface Width Recommendations for M301
5.2.1.1 Transfer Surface Width Recommendations for M301 The Committee recommends a transfer surface of 28 inches minimum width for equipment used by patients in a supine, side-lying,...