Trailhead signs shall be located centered at the back of a 30- by 48-inch (760- by 1,220-millimeter) minimum clear floor or ground space....
Search Results "Ground Floor"
Commonly Searched Documents
-
7.4.11.1 Clear Space
-
§ 38.83(a)(1) General
) complying with either paragraph (b) or (c) of this section and sufficient clearances to permit at least two wheelchair or mobility aid users to reach areas, each with a minimum clear floor...
-
Carpet [§302.2]
Exposed edges must have trim on the entire length of the exposed edge and be fastened to the floor to prevent curling....
-
R302.7 Surfaces
R302.7 Surfaces. The surfaces of pedestrian access routes and elements and spaces required to comply with R302.7 that connect to pedestrian access routes shall be firm, stable, and...
-
Water Hydrants
The surface at the base of water hydrants at recreation areas must be firm and stable with a 60-inch turning radius. See the "Surfaces" rule of thumb above. You can also build a wood...
-
Executive Summary
Over two million people in the United States use a wheelchair for mobility. These Americans not only rely on their assistive technology to complete simple, daily tasks, but they also...
-
Development of Surface Roughness Standards for Pathways Used by Wheelchair Users: Final Report
Development of Surface Roughness Standards for Pathways Used by Wheelchair Users: Final Report December 2014 Human Engineering Research Laboratories VA Pittsburgh...
-
3.2.3 Surface
The ground surface in all camp living areas shall be firm and stable. The type of surface should be appropriate to the setting and level of development....
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
11B-604.3.1 Size
ETA Editor's Note The CBC 11B-604.3.1 requirement for maneuvering space in front of accessible water closets exceeds the 2010 ADA Standards requirement for water closet clear floor...
-
A4.5.3 Carpet
When both carpet and padding are used, it is desirable to have minimum movement (preferably none) between the floor and the pad and the pad and the carpet which would allow the carpet to...
-
Surface: ADA Standard Section 810.2.1
Bus stop boarding and alighting areas shall have a firm, stable surface.
-
11B-810.2.1 Surface
Bus stop boarding and alighting areas shall have a firm, stable surface.
-
407.2.3.1 Floor Designation
407.2.3.1 Floor Designation. Floor designations complying with 703.2 and 703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
- Figure 1007.3.2 Golf Club Reach Range Area – Drawing from the U.S. Access Board
-
1011.2.3 Slope
This section requires the slope of the clear ground space to not be steeper than 1:48 in any direction....
-
302.2 Carpet
Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge. Carpet edge trim shall comply with 303....
-
302.2 Carpet
Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge. Carpet edge trim shall comply with 303....
-
302.2 Carpet
Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge. Carpet edge trim shall comply with 303....
- Magnuson Group UMEA Waste Receptacles
- Landscape Forms Inc. Select Modular Steel Recycling Units
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....