The clearance between the platform sill and the edge of any runway landing shall be 1¼ inch (32 mm) maximum....
Search Results "Door Maneuvering Clearance"
-
11B-410.4 Platform to runway clearance
-
11B-206.5.3 Transient lodging facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with Section...
-
502.5 Vertical Clearance
Parking spaces for vans and access aisles and vehicular routes serving them shall provide a vertical clearance of 98 inches (2490 mm) minimum. Advisory 502.5 Vertical Clearance....
-
Vertical Clearance [§502.5]
Vertical Clearance [§502.5] A 98” minimum vertical clearance is required for van parking spaces/ access aisles and the vehicle route to these spaces from an entrance and from these...
-
502.5 Vertical Clearance
Parking spaces for vans and access aisles and vehicular routes serving them shall provide a vertical clearance of 98 inches (2490 mm) minimum. Advisory 502.5 Vertical Clearance....
-
4.1.3(7)(a)
(a) At each accessible entrance to a building or facility, at least one door shall comply with 4.13....
-
11B-306.2.2 Maximum depth
Toe clearance shall extend 25 inches (635 mm) maximum under an element....
-
11B-306.2.2 Maximum depth
Toe clearance shall extend 25 inches (635 mm) maximum under an element....
-
11B-306.2.2 Maximum depth
Toe clearance shall extend 25 inches (635 mm) maximum under an element....
- ADAEZ Pro Plus Automatic Door Opener Quick Tip Spacing the Door Arm Video
-
Toilet Paper Dispensers
In the final rule, the specified clearance between grab bars and dispensers mounted above them has been revised for consistency with the grab bar specifications in section 609....
- Access Board: Single User Toilet Room Size and Layout
-
F206.5.1 Entrances
Each entrance to a building or facility required to comply with F206.4 shall have at least one door, doorway, or gate complying with 404....
-
206.5.1 Entrances
Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
-
Exit Doors: ADA Standard Section 216.4.1
Section 216.4.1 covers scoping requirements in the current ADA Standards for signs at exit doors.
-
1132A.6 Closer-effort to operate doors
1132A.6 Closer-effort to operate doors....
-
F206.5.2 Rooms and Spaces
Within a building or facility, at least one door, doorway, or gate serving each room or space complying with these requirements shall comply with 404....
-
206.5.2 Rooms and Spaces
Within a building or facility, at least one door, doorway, or gate serving each room or space complying with these requirements shall comply with 404....
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to hinged...
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to hinged...
-
206.5.1 Entrances
Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
-
§ 38.157(a)
(a) Any stepwell or doorway immediately adjacent to the driver shall have, when the door is open, at least 2 foot-candles of illumination measured on the step tread....
-
206.5.2 Rooms and Spaces
Within a building or facility, at least one door, doorway, or gate serving each room or space complying with these requirements shall comply with 404....
-
F206.5.3 Transient Lodging Facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with 806.2...