Is the ramp width, measured between the handrails, at least 36 inches? [ADA Standards § 4.8.3]    Yes    No...
Search Results "Built-Up Curb Ramp"
Commonly Searched Documents
-
f-iii
-
Wet Conditions [§405.10]
Wet Conditions [§405.10] Landings subject to wet conditions must be designed to prevent the accumulation of water. Landings are permitted slopes not steeper than 1:48 to allow for...
-
1007.2, Item 8
Ramps complying with Section 1010, and Chapter 11A, Sections 1114A and 1122A, or Chapter 11B, 11B-405, as applicable....
-
1009.2, Item 8
Ramps complying with Section 1012, and Chapter 11A, Sections 1114A and 1122A, or Chapter 11B, 11B-405, as applicable....
-
Section 35.151(d) Scope of Coverage (Section-by-Section Analysis)
proposing § 35.151(d) to clarify that the requirements established by this section, including those contained in the proposed standards, prescribe what is necessary to ensure that fixed or built-in...
-
4f.
Is a level landing, at least 60 inches by 60 inches, provided where a ramp changes direction? [ADA Stds 4.8.4] Yes _____ No _____...
-
4.8.5(5)
(5) Top of handrail gripping surfaces shall be mounted between 34 in and 38 in (865 mm and 965 mm) above ramp surfaces....
-
1.9.1.2.3
1.9.1.2.3 Any curb or sidewalk intended for public use that is constructed in this state with private funds....
-
1.9.1.2.3
1.9.1.2.3 Any curb or sidewalk intended for public use that is constructed in this state with private funds....
-
405.7.4 Change in Direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum....
-
405.7.4 Change in Direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum....
-
3. Exception to Ramp Running Slope
The Committee reviewed and discussed the provisions on slopes for ramps as they apply to architectural elements in the built environment....
-
4.8.5(2)
(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top and bottom of the ramp segment and shall be parallel with the floor or ground surface (see Fig...
- Irwin Seating Company ADA Transfer Arm
- EZ-ACCESS Transitions® Angled Entry Mat
- EZ-ACCESS Transitions® Angled Entry Plate
- Hollaender Manufacturing Company ADA Railing Systems
- PromenAid Handrail System
- Madden Manufacturing Round Handrail (ADA Compliant)
-
B5. Curb Ramp
Is a curb ramp provided between the vehicle pull up area and the access aisle (see figure above) or the access aisle and the accessible route (see figure on page 9) to the accessible entrance...
-
405.7.4 Change in Direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum....
-
11B-407.2.2.3 Audible signals
Audible signals shall sound once for the up direction and twice for the down direction, or shall have verbal annunciators that indicate the direction of elevator car travel....
-
11B-407.2.2.3 Audible signals
Audible signals shall sound once for the up direction and twice for the down direction, or shall have verbal annunciators that indicate the direction of elevator car travel....
-
11B-407.2.2.3 Audible signals
Audible signals shall sound once for the up direction and twice for the down direction, or shall have verbal annunciators that indicate the direction of elevator car travel....