Accessibility scoping requirements for elevators and lifts are located in Sections 11B-206.6 and 11B-207.6 [sic]; technical requirements are located in Sections 11B-407, 11B-408, 11B-409...
Search Results "Wet Location"
-
11B-409.1 General
-
11B-409.1 General
Accessibility scoping requirements for elevators and lifts are located in Sections 11B-206.6 and 11B-207.6 [sic]; technical requirements are located in Sections 11B-407, 11B-408, 11B-409...
-
3.10 Cinemark 22, 2600 West Avenue I, Lancaster, California
location...
- Behavioral Health Integration Capacity Assessment Introductory Webinar
-
Hospitals: ADA Standard Section 217.4.6
Section 217.4.6 covers scoping requirements in the current ADA Standards for TTYs in hospitals.
-
11B-217.4.6 Hospitals
Where at least one public pay telephone is provided serving a hospital emergency room, hospital recovery room, or hospital waiting room, at least one public TTY shall be provided at each location...
-
11B-217.4.6 Hospitals
Where at least one public pay telephone is provided serving a hospital emergency room, hospital recovery room, or hospital waiting room, at least one public TTY shall be provided at each location...
-
11B-809.12 Electrical receptacles, controls and switches
Electrical receptacles on branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no obstruction...
-
11B-809.12 Electrical receptacles, controls and switches
Electrical receptacles on branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no obstruction...
-
6. Where multiple swings in a swing bay are provided, Section 240.2.1.1 (one of each type) requires one swing to be located on an accessible route. If an accessible route is provided to more than one swing, can each swing be counted as an accessible ground level play component? If one is an infant seat and another a sling seat, are those considered two different types?
Where multiple swings in a swing bay are provided, Section 240.2.1.1 (one of each type) requires one swing to be located on an accessible route....
-
Compartment Doors
Specifications are provided for doors, including their location....
-
A4.5.1 General
Soft loose surfaces such as shag carpet, loose sand or gravel, wet clay, and irregular surfaces such as cobblestones can significantly impede wheelchair movement....
-
RECOMMENDATIONS
PERCENTILE) Sweep width 1.2 m Inline skaters 1.5 m Horizontal alignment 27 m Recumbent bicyclists 26.8 m Stopping sight distance (wet...
-
Bus Boarding and Alighting Areas: ADA Standard Section 810.2
At bus stops where a shelter is provided, the bus stop pad can be located either within or outside of the shelter....
-
11B-411.2.1.7.4 Adjacency assignment
Exception: The most adjacent elevator serving the selected floor shall be assigned by hall call consoles located outside the elevator landing....
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and the...
-
Controls: ADA Standard Section 607.5
Section 607.5 covers the current ADA Standards bathtub controls.
-
11B-411.2.1.7.4 Adjacency assignment
Exception: The most adjacent elevator serving the selected floor shall be assigned by hall call consoles located outside the elevator landing....
-
Grab Bars: ADA Standard Section 604.8.1.5
Section 604.8.1.5 covers the current ADA Standards for grab bars in wheelchair accessible compartments.
-
Amusement Attraction
Any facility, or portion of a facility, located within an amusement park or theme park which provides amusement without the use of an amusement device....
-
907.5.2.3.3.1 Wired equipment.
The future extension of the existing wiring from the unit smoke alarm locations to required locations for visibleĀ appliances....
-
11B-809.9.2 Clear width
U-shaped kitchens, designed with parallel approach at a sink, range, cooktop or other fixtures and appliances located at the base of the U without knee and toe clearance, shall provide a...
-
Application Based on Building or Facility Use: ADA Standard Section 201.2
Section 201.2 covers the application of the most current requirements based on the building or facility use.
-
11B-809.9.2 Clear width
U-shaped kitchens, designed with parallel approach at a sink, range, cooktop or other fixtures and appliances located at the base of the U without knee and toe clearance, shall provide a...