703.5.6 Height from Finish Floor or Ground. Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground. EXCEPTION: Visual characters indicating...
Search Results "Toilet Room"
Commonly Searched Documents
-
703.5.6 Height from Finish Floor or Ground
-
703.5.3 Style
703.5.3 Style. Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-202.2 Additions
Each addition to an existing building or facility shall comply with the requirements for new construction and shall comply with 11B-202.4 _|Alterations; Path of Travel...
-
§ 36.403(g) Duty to provide accessible features in the event of disproportionality.
(g) Duty to provide accessible features in the event of disproportionality.
-
F216.1 General
Signs shall be provided in accordance with F216 and shall comply with 703.
-
(1)(a)
(a) The minimum clear floor area should be 35 inches (890 mm) by 60 inches (1525 mm). Permanently installed fixtures may overlap this area a maximum of 6 inches (150 mm), if the...
-
11B-703.1 General
11B-703.1 General. Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two...
-
11B-703.5.3 Style
11B-703.5.3 Style. Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
§ 38.123(a)(1)
(1) The minimum clear floor area shall be 35 inches by 60 inches. Permanently installed fixtures may overlap this area a maximum of 6 inches, if the lowest portion of the fixture is...
-
11B-202.2 Additions
Each addition to an existing building or facility shall comply with the requirements for new construction and shall comply with 11B-202.4 _|Alterations; Path of Travel...
-
11B-703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-703.1 General
Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
11B-202.2 Additions
Each addition to an existing building or facility shall comply with the requirements for new construction and shall comply with 11B-202.4. Advisory 11B-202.2 Additions. An...
-
Bobrick Recessed Multi-Roll Toilet Tissue Dispenser B-3888 Elevations
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley Partition Mounted Stainless Steel Toilet Tissue Dispenser 5422 Plan
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bobrick ClassicSeries Surface-Mounted Toilet Tissue Dispenser B-76867 Elevations
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bobrick Recessed Multi-Roll Toilet Tissue Dispenser B-4388 Elevations
Requires the Premium User plan or above. (Login or upgrade your account!)
-
American Specialties Recessed Dual Roll Toilet Paper Holder Model 74022
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bobrick Surface-Mounted Toilet Tissue Dispenser for Two Rolls B-27460
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bobrick Surface-Mounted Toilet Tissue Dispenser with Hood B-6699 Elevations
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bobrick Recessed Toilet Tissue Dispenser with Storage for Extra Roll B-663
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bobrick ClassicSeries Surface-Mounted Toilet Tissue Dispenser B-7685 Elevations
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bobrick Surface-Mounted Toilet Tissue Dispenser with Hoods B-69997 Elevations
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bobrick ClassicSeries Surface-Mounted Toilet Tissue Dispenser B-7686 Elevations
Requires the Premium User plan or above. (Login or upgrade your account!)