A seat in a standard roll-in shower compartment shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back wall to a point...
Search Results "Signage Height"
Commonly Searched Documents
-
11B-610.3 Shower compartment seats
-
11B-806.2.3.1 Personal lift device floor space
There shall be a clear space under the bed for the use of a personal lift device. The clear space shall extend under the bed parallel to the long side and be adjacent to an...
-
Companion Seats
Several commenters urged the Department to ensure that companion seats are positioned in a manner that places the user at the same shoulder height as their companions using mobility devices...
- Seton Pavement Tool Plastic Graphic Stencils - ISA Symbol (California DOT) S-3048 D - PP261
- Seton Flexible Bollard Sign Post Systems
- Seton Pavement Tool Plastic Graphic Stencils - ISA Symbol (Texas DOT) S-3148 D - PP262
-
11B-604.9 Water closets and toilet compartments for children's use
Water Closet Centerline 12 inches (305 mm) 12 to 15 inches (305 to 381 mm) 15 to 18 inches (381 to 457 mm) Toilet Seat Height...
-
Chapter 3: Study findings
[See subsections ...]
-
M301.2.2 Sunset
The low transfer position height, Item A of M301.2.1, shall cease to have effect on [Insert date 5 years after date of publication in the Federal Register]....
-
Hoistway Signs: ADA Standard Section 408.2.3
Section 408.2.3: covers the current ADA Standards for limited-use/limited-application elevator hoistway signs.
-
Style: ADA Standard Section 703.2.3
Characters shall be sans serif. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
Assistive Listening Systems: ADA Standard Section 703.7.2.4
Assistive listening systems shall be identified by the International Symbol of Access for Hearing Loss complying with Figure 703.7.2.4.
-
Post-Mounted Objects: ADA Standard Section 307.3
Section 307.3 covers the current ADA Standards for the protrusion limits for post-mounted objects.
-
11B-408.2.3 Hoistway signs
Signs at elevator hoistways shall comply with Section 11B-407.2.3.1.
-
11B-703.7.2.4 Assistive listening systems
Assistive listening systems shall be identified by the International Symbol of Access for Hearing Loss complying with Figure 11B-703.7.2.4.
-
11B-703.2.3 Style
Characters shall be sans serif. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-307.3 Post-mounted objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum...
- Access Board: International Symbol of Accessibility (ISA) Technical Requirements
-
Can you provide recommended signage for ADA accessible spaces?
RESPONSE: Required identification signs for accessible EVCS vehicle spaces are indicated in CBC Chapter 11B Section 11B-812.8 and required vehicle space surface markings are...
-
F216.6 Entrances
Where not all entrances comply with 404, entrances complying with 404 shall be identified by the International Symbol of Accessibility complying with 703.7.2.1. Directional signs...
-
216.6 Entrances
Where not all entrances comply with 404, entrances complying with 404 shall be identified by the International Symbol of Accessibility complying with 703.7.2.1. Directional signs...
-
216.6 Entrances
216.6 Entrances. Where not all entrances comply with 404, entrances complying with 404 shall be identified by the International Symbol of Accessibility complying with 703.7.2.1....
-
Selection of Variables
, sitting; arm length (acromion to fingertip); biacromial breadth; buttock-heel length; eye height, sitting; foot breadth; foot length; knee height, sitting; maximum elbow span; sitting...
-
11B-502.8.2 Lettering
The additional sign shall clearly state in letters with a minimum height of 1 inch (25 mm) the following: "Unauthorized vehicles parked in designated accessible spaces not displaying...