Elevator hoistway and car doors shall open and close automatically....
Search Results "Shower Door"
-
11B-407.3.2 Operation
-
11B-233.3.1.2.6.5 Additional requirements.
Interior door opening width complying with Section 11B-404.3.1. 3. Door and gate hardware complying with Section 11B-404.2.7. 4....
- Symmons® Allura Tub/Hand Shower System S-4705
-
404.3.1 Clear Width
The minimum clear width for automatic door systems in a doorway shall be based on the clear opening provided by all leaves in the open position....
- American Bath Enterprises, Inc. AccessaBath Shower System
-
404.3.1 Clear Width
The minimum clear width for automatic door systems in a doorway shall be based on the clear opening provided by all leaves in the open position. [ECTCR UFAS 4.13.5]...
-
404.3.1 Clear Width
The minimum clear width for automatic door systems in a doorway shall be based on the clear opening provided by all leaves in the open position....
-
404.2.7 Door and Gate Hardware
404.2.7 Door and Gate Hardware. Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 309.4....
-
H6
If the entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the door swing?...
- Besam SL500 A02 for sustainable automatic doors
- American Standard FloWise® Commercial Shower System Kit
-
404.2.7 Door and Gate Hardware
Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 309.4....
-
404.2.7 Door and Gate Hardware
Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 309.4....
-
11B-224.8.2 More than 50-bed facilities
Facilities with more than 50 beds that provide common use bathing facilities, shall provide at least one roll-in shower with a seat that complies with Section 11B-608....
-
11B-224.8.2 More than 50-bed facilities
Facilities with more than 50 beds that provide common use bathing facilities, shall provide at least one roll-in shower with a seat that complies with Section 11B-608....
-
Thresholds at Doorways
The 1991 Standards, at section 4.13.8, require the height of thresholds at doorways not to exceed ½ inch and thresholds at exterior sliding doors not to exceed ¾ inch....
-
H2
Does the door to the toilet room provide at least 32 inches clear passage width when the door is open 90 degrees? [ADA Standards § 4.13.5] Yes No...
-
M2
Does the door to the toilet room provide at least 32 inches clear passage width when the door is open 90 degrees? [ADA Standards § 4.13.5] Yes No...
- American Specialties Folding Shower Seat 8205-L
-
Standard Stall
The clearances required for stall doors are different than those specified for conventional passage doors and gates in 4.13.6 since partition doors are generally lighter and easier to open...
-
11B-809.10.5.3 Controls
Exception: Shower spray units are not required in bathtubs....
-
11B-809.10.5.3 Controls
Exception: Shower spray units are not required in bathtubs....
-
Restrooms Main Lobby
The restroom vestibule door does not have the required minimum of 18" maneuvering clearance on the latch side of the door. See Standards § 4.13.6. l....
-
(4) [sic] Thresholds at exterior doors
Subject to the exceptions for thresholds and changes in level at exterior areas constructed of impervious materials, the final Guidelines continue to specify that thresholds at exterior doors...