Public housing facilities with residential dwelling units available for public use shall comply with Section 11B-233....
Search Results "Multistory Dwelling Unit (FHA)"
-
11B-233.1 General
-
11B-233.1 General
This section addresses long-term living (non-transient), public housing dwelling units....
-
11B-233.3.1.2.6 Public housing facility site impracticality
The site impracticality tests in this section may be used to determine the number of required residential dwelling units with adaptable features in buildings without an elevator, located...
-
B. Scoping Requirements for Units with Communication Features
Scoping Requirements for Units with Communication Features The ADA and ABA Accessibility Guidelines require at least 2 percent of the residential dwelling units in a facility to provide...
-
1(2) Site impracticality
Covered multifamily dwellings with elevators shall be designed and constructed to provide at least one accessible entrance on an accessible route, regardless of terrain or unusual characteristics...
-
4.1.3(12) Storage, Shelving and Display Units
(12) Storage, Shelving and Display Units:...
-
F244.2 Camping Units with Mobility Features
Where different types of camping units are provided (e.g., camping units for recreational vehicles only; camping units for tent camping only; and camping units with camp shelters), Table...
-
F244.2 Camping Units with Mobility Features
Table F244.2 Camping Units with Mobility Features Total Number of Camping Units Provided in Camping Facility Minimum Number of Camping Units with Mobility Features Required...
-
11B-606.2 Clear floor space
In residential dwelling units, cabinetry shall be permitted under lavatories and kitchen sinks provided that all of the following conditions are met: (a) the cabinetry can be removed...
-
11B-606.2 Clear floor space
In residential dwelling units, cabinetry shall be permitted under lavatories and kitchen sinks provided that all of the following conditions are met: (a) the cabinetry can be removed...
-
Site Impracticality Determinations
For covered multifamily dwellings with elevators, the final Guidelines would not exempt these dwellings from the Act's accessibility requirements....
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4. Controls and faucets shall allow the user to close and open the water supply....
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4. Controls and faucets shall allow the user to close and open the water supply....
-
F245.2 Picnic Units with Mobility Features
This section requires picnic facilities to provide a minimum number of picnic units with mobility features as discussed below....
-
F244.2.3 Elements Within Camping Units with Mobility Features
Elements within camping units required to provide mobility features shall comply with F244.2.3....
-
F245.2.5 Elements Within Picnic Units with Mobility Features
Elements within picnic units required to provide mobility features shall comply with F245.2.5....
-
11B-809.10.6.1 Size
When one or more shower stalls are provided within the same dwelling unit, as least one shower stall shall comply with one of the following: A transfer type shower compartment...
-
Camping Units
A camping unit commonly includes the camp living area, a parking spur, and a space to pitch a tent (figure 60)....
-
11B-206.2.3 Multi-story buildings and facilities
through 11B-809.4, residential dwelling units with adaptable features complying with Sections 11B-809.6 through 11B-809.12, all common use areas serving residential dwelling units with...
-
1133A.7 Knee and toe space
1133A.7 Knee and toe space. Knee and toe space, when required by Section 1133A, shall comply with the following:
-
1133A.2.1, Item 2
2. U-shaped kitchens, designed with a cooktop or sink located at the base of the U, which provides a knee and toe space in accordance with Section 1133A.7 to allow for a forward...
-
1132A.3, Item 6
6. The width of any component in the means of egress system shall not be less than the minimum width required by Section 1005.
-
1133A.7, Item 2
2. The knee and toe space shall be 30 inches (762 mm) wide minimum, centered on the sink, countertop or appliance.