above the finish floor or ground at a depth of 8 inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge of a counter with...
Search Results "Minimum Dimension"
-
11B-805.6 Hand washing fixtures, lavatories and sinks
-
11B-805.6 Hand washing fixtures, lavatories and sinks
above the finish floor or ground at a depth of 8 inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge of a counter with...
-
11B-404.2.3 Clear width
Door openings shall provide a clear width of 32 inches (813 mm) minimum....
-
11B-404.2.3 Clear width
Door openings shall provide a clear width of 32 inches (813 mm) minimum....
-
Clear Width: ADA Standard Section 404.2.3
Section 404.2.3 covers the current ADA Standards for clear width at manual doors, doorways and manual gates that are part of an accessible route.
-
11B-1003.3.2 Boarding pier clearances
Every 10 feet (3048 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1524 mm) wide minimum....
-
11B-1003.3.2 Boarding pier clearances
Every 10 feet (3048 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1524 mm) wide minimum....
-
11B-405.7.3.1
Bottom landings shall extend 72 inches (1829 mm) minimum in the direction of ramp run....
-
11B-405.7.3.1
Bottom landings shall extend 72 inches (1829 mm) minimum in the direction of ramp run....
-
Duration: ADA Standard Section 408.3.2.2
Section 408.3.2.2 covers the current ADA Standards for the duration of swinging doors on limited-use/limited-application elevator.
-
Door Delay: ADA Standard Section 407.3.5
Section 407.3.5 covers the current ADA Standards for elevator door delay.
-
11B-813.2.1.4 Capacity
Adult changing tables shall provide a minimum weight capacity of 300 pounds (136 kg)....
-
11B-502.6.1 Finish and size
Parking identification signs shall be reflectorized with a minimum area of 70 square inches (45,161 mm2)....
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-502.6.1 Finish and size
Parking identification signs shall be reflectorized with a minimum area of 70 square inches (45,161 mm2)....
-
11B-813.2.1.4 Capacity
Adult changing tables shall provide a minimum weight capacity of 300 pounds (136 kg)....
-
Ambulatory Accessible Compartment
Throughout the new guidelines, the Board has sought to specify dimensions as a range instead of in absolute terms where practicable to facilitate compliance without compromising accessibility...
-
5.3.2.1 Transfer Sides Recommendation for Stretchers
5.3.2.1 Transfer Sides Recommendation for Stretchers On stretchers, the transfer surface is oriented along the long dimension of the surface on which patients are in the supine, prone...
-
9. Exterior Ramps
[ADA Stds. 4.8.3] Yes __ No __ N/A __ Comments: _______________________________ d. do the exterior ramps have running slopes that are 1:12 or less (critical dimension of 2" or less...
-
4.4.4 Clear Floor or Ground Space
The long dimension of the clear space shall be roughly perpendicular to the length of the bench....
-
Department of Justice method
Use the tape measure and measure the open gap at the downhill end of the level to establish the critical dimension....
-
11B-1003.3.1 Boat slip clearance
Boat slips shall provide clear pier space 60 inches (1524 mm) wide minimum and at least as long as the boat slips....