(69.9mm) depth 3-1/4" (82.6mm) or 4-5/8" (117.5mm) frame depth High thermal performance Moderate traffic application FEATURES: NexGen™ Thermal Barrier SystemNexGen™ Energy...
Search Results "Low Energy Door"
Commonly Searched Documents
- Kawneer North America NX-8900 Terrace Doors
- 307.4 Door Opening Vertical Clearance
- Oasis Barrier-Free Universal Split-Level VersaCooler II P8ACSL
- Elkay Wall Mount Bi-Level ADA Water Cooler EZSTL8LC
- Murdock Manufacturing Barrier-Free 14-Gage Stainless Steel Bi-Level Wall Mount Water Cooler
- Halsey Taylor Bi-Level Barrier-Free Cooler
-
4.1.6(4)(d)
(d) Doors....
- LaCantina Contemporary Clad Door System
- Access Board: Maneuvering Clearance at Recessed Doors
-
1132A.4, Item 4
Secondary exterior doors onto decks, patios or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...
-
§ 36.304(b)(8)
(8) Widening doors;...
-
Sec.36.304(b)(8)
(8) Widening doors;...
- DORMA KTC-2 Revolving Door
-
29.1 Q. Is it acceptable to design a bathroom with an in-swinging 2'10 door which can be retrofitted to swing out in order to provide the necessary clear floor space in the bathroom?
Thus, for a bathroom, there must be sufficient maneuvering space and clear floor space so that a person using a wheelchair or other mobility aid can enter and close the door, use the fixtures...
-
Re: How to Use the Pressure Gauge Tool
WARNING - We have stopped carrying the HMC International spring-type door pressure gauges shown in the video because the last two large shipments we received were all exactly one pound off...
-
602.6 Water Flow
The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit. The angle of the water stream shall...
-
602.6 Water Flow
The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit. The angle of the water stream shall...
-
602.6 Water Flow
602.6 Water Flow. The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit. The angle of the...
-
11B-602.6 Water flow
The spout shall provide a flow of water 4 inches (102 mm) high minimum and shall be located 5 inches (127 mm) maximum from the front of the unit. The angle of the water stream shall...
-
4.15.3 Spout Location
The spouts of drinking fountains and water coolers shall be at the front of the unit and shall direct the water flow in a trajectory that is parallel or nearly parallel to the front...
-
4.15.3 SPOUT LOCATION
The spouts of drinking fountains and water coolers shall be at the front of the unit and shall direct the water flow in a trajectory that is parallel or nearly parallel to the front...
-
Synthesis of Literature Relevant to Roundabout Signalization to Provide Pedestrian Access - Final Report
Prepared by: Vaughan W. Inman Science Applications International Corporation and Gregory W. Davis Federal Highway Administration, RD&T 6300 Georgetown...
-
11B-602.6 Water flow
11B-602.6 Water flow. The spout shall provide a flow of water 4 inches (102 mm) high minimum and shall be located 5 inches (127 mm) maximum from the front of the unit. The angle of...
-
11B-602.6 Water flow
The spout shall provide a flow of water 4 inches (102 mm) high minimum and shall be located 5 inches (127 mm) maximum from the front of the unit. The angle of the water stream shall...