Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
Search Results "Grade Level Exit"
Commonly Searched Documents
-
703.5.3 Style
-
703.5.6 Height From Finish Floor or Ground
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground. EXCEPTION: Visual characters indicating elevator car controls shall not be required to...
-
703.1 General
Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual,...
-
703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the...
-
703.4.2 Location
703.4.2 Location. Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with...
-
216.1 General
216.1 General. Signs shall be provided in accordance with 216 and shall comply with 703. EXCEPTIONS: 1. Building directories, menus, seat and row designations in assembly areas,...
-
703.1 General
703.1 General. Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
703.5.6 Height from Finish Floor or Ground
703.5.6 Height from Finish Floor or Ground. Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground. EXCEPTION: Visual characters indicating...
-
703.5.3 Style
703.5.3 Style. Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
4.1.2(7) Building Signage
(7) Building Signage. Signs which designate permanent rooms and spaces shall comply with 4.30.1, 4.30.4, 4.30.5 and 4.30.6. Other signs which provide direction to, or information...
-
F216.1 General
Signs shall be provided in accordance with F216 and shall comply with 703.
-
4.1.1(7)
(7) All signs shall comply with 4.30. Elements and spaces of accessible facilities which shall be identified by the International Symbol of Accessibility are: (a) Parking spaces...
-
11B-703.1 General
11B-703.1 General. Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two...
-
11B-703.5.3 Style
11B-703.5.3 Style. Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-703.1 General
Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
- Rockwood Manufacturing Company BFM689 BFM Series Unisex ADA Toilet Room Molded Plastic Sign
- Rockwood Manufacturing Company BFM687 BFM Series Men's ADA Toilet Room Molded Plastic Sign
- Rockwood Manufacturing Company BFM688 BFM Series Women's ADA Toilet Room Molded Plastic Sign
-
Common Use Circulation Paths in Employee Work Areas
Standards at section 203.9, require employee work areas in new construction and alterations only to be designed and constructed so that individuals with disabilities can approach, enter, and exit...
- Seton California Code ADA Women's Rest Room Sign with ISA - Black 84949
-
502.4 Floor or Ground Surfaces
Access aisles shall be at the same level as the parking spaces they serve. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
502.4 Floor or Ground Surfaces
Access aisles shall be at the same level as the parking spaces they serve. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....