Exception 2 does not require emergency transportable housing units required to provide mobility features to be dispersed among the various types of units in the facility or to provide choices...
Search Results "EPAMDs: Electronic Personal Assistive Mobility Devices"
-
233.3.6 Dispersion (Exception 2), F233.3.5 Dispersion (Exception 2), F233.4.6 Dispersion (Exception 2)
-
§ 38.159(d)(1) Design load
shall restrain a force in the forward longitudinal direction of up to 2,000 pounds (8,880 N) per securement leg or clamping mechanism and a minimum of 4,000 pounds (17,760 N) for each mobility...
-
11B-404.3 Automatic and power-assisted doors and gates
Low-energy and power-assisted doors shall comply with ANSI/BHMA A156.19. Advisory 11B-404.3 Automatic and power-assisted doors and gates....
-
11B-404.3 Automatic and power-assisted doors and gates
Low-energy and power-assisted doors shall comply with ANSI/BHMA A156.19. Advisory 11B-404.3 Automatic and power-assisted doors and gates. ...
-
Motor Impairments
Motor Impairments: To evacuate individuals with motor impairments, employers can purchase evacuation devices....
-
5.2 Distributing Receivers
Assist listeners in selecting the appropriate coupling arrangement (headphones, neckloop, earbuds, etc.). Briefly instruct users in how to operate the receiver....
-
4.21.4 Grab Bars
On the one hand, transfers are typically only made into shower chairs outside the shower and with a caregiver’s assistance....
- inLOOP Personal Loop 400
-
11B-1002.6.2 Transfer height
The height of transfer device seats shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor....
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor....
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor....
-
F245.2.1 Picnic Facilities with Two or Fewer Picnic Units
Where picnic facilities contain two or fewer picnic units, each picnic unit shall provide mobility features complying with F245.2....
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor....
-
1002.6.2 Transfer Height
The height of transfer device seats shall be 14 inches (355 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
§ 382.39 Provision of services and equipment
(3) Carriers shall not leave a passenger with a disability unattended in a ground wheelchair, boarding wheelchair, or other device, in which the passenger is not independently mobile...
-
21. BRAND STANDARDS, QUALITY ASSURANCE INSPECTIONS
(ii) The provision of information regarding ADA Contact Person in in-room guest materials as set forth in Paragraph 28....
- The Accessibility Management Platform (AMP) - AMP for Mobile
-
2.4.1. Replacement Costs
The Final RA estimates the costs to replace captioning and audio description hardware and devices over the time frame of the analysis. ...
-
4.1.3(19)(b)
Such assembly areas, if (1) they accommodate at least 50 persons, or if they have audio-amplification systems, and (2) they have fixed seating, shall have a permanently installed assistive...
- LowVis Guide: Indoor Navigation for the Visually Impaired
-
809.1 General