According to FARE (Food Allergy and Research Education) “Fifteen million Americans have food allergies – and they are eager to find restaurants [and other venues] that can...
Search Results "Diagnostic Room"
Commonly Searched Documents
-
Food Allergies and Sensitivities
-
Best Practices in the Design of Toileting and Bathing Facilities for Assisted Transfers
Best Practices in the Design of Toileting and Bathing Facilities for Assisted Transfers Final Report August 1, 2001 Jon A. Sanford, Project Director Atlanta Research...
-
Captioning Audio/Visual Materials
The best way to use captioned audio/visual materials is to purchase or use videos that already have closed captions. If this is not possible or videos must be produced in-house,...
-
11B-809.10.7.5 Controls
Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum.
-
11B-809.10.8.3 Cabinets
Cabinets shall be removable without the use of specialized knowledge and/or tools. The finished floor shall extend to the wall under the lavatory.
-
In Your Guest Room:
the shortest route. 1.1.2 Count the number of doors and turns from your room door to exits. 1.1.3 Make sure the exits are unlocked....
-
§ 36.406(c) Places of lodging.
subject to this part shall comply with the provisions of the 2010 Standards applicable to transient lodging, including, but not limited to, the requirements for transient lodging guest rooms...
-
217.4.6 Hospitals
Where at least one public pay telephone is provided serving a hospital emergency room, hospital recovery room, or hospital waiting room, at least one public TTY shall be provided at each...
-
M303.3.3.2 Cross Slope
The cross slope of ramp runs shall not be steeper than 1:48.
-
M303.3.3 Ramped
Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3.
-
5.8.1.2.1 Ramped Entry Slope Recommendations
5.8.1.2.1 Ramped Entry Slope Recommendations The Committee recommends that raised platforms have a ramp with slopes that do not exceed the following: At 0 to 1½ inches, the...
-
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms.
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height. Edge protection is not required on platforms 1 ½ inches or less in height.
-
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms Recommendations Description: Entry to wheelchair spaces on raised surfaces greater than ¼ inch in height requires a...
-
5.8.1.2.2 Single Ramped Entry - Edge Protection on the Platform and Platform Sides Recommendations
5.8.1.2.2 Single Ramped Entry - Edge Protection on the Platform and Platform Sides Recommendations The Committee recommends a two-inch high edge protection on the back of the...
-
5.8.1.2.1 Ramped Entry Slope
5.8.1.2.1 Ramped Entry Slope. Raised platforms should have a ramp with slopes that do not exceed the following: Rise 0 to 1 ½ inches – 1:2 Slope Rise >1 ½ to 2 ½ inches – 1:8...
-
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces.
-
5.8.1.2.3 Double Ramped Entry – Edge Protection on the Platform Sides
5.8.1.2.3 Double Ramped Entry – Edge Protection on the Platform Sides. A minimum 2 inch high edge protection must be provided on both sides of the platform for double ramped entry...
-
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces Recommendations
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces Recommendations
-
5.8.1.2.2 Single Ramped Entry – Edge Protection on the Platform and Platform Sides
5.8.1.2.2 Single Ramped Entry – Edge Protection on the Platform and Platform Sides. A 2 inch high edge protection must be provided on the back of the platform, opposite the entry...
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations The Committee recommends that no edge protection be required on platforms of 1½ inches or less...
-
5.8.1.2.3 Double Ramped Entry - Edge Protection on the Platform sides Recommendations
5.8.1.2.3 Double Ramped Entry - Edge Protection on the Platform sides Recommendations The Committee recommends a minimum two-inch high edge protection on both sides of the...
-
M303.2.5 Surfaces
Wheelchair space surfaces shall not slope more than 1:48 in any direction.
-
M303.3.3.2 Cross Slope
The cross slope of ramp runs shall not be steeper than 1:48.