protocol: From initial setup, just the horizontal distance between the WMD and platform was incrementally increased by placing plywood blocks of 3.5” (8.9cm) width between the transfer station...
Search Results "Deputy Clerks' Station"
-
Adjustable gap protocol
-
§ 38.113(d)(1) Requirements
Cars which provide level-boarding in stations with high platforms shall be coordinated with the boarding platform or mini-high platform design such that the horizontal gap between a car...
-
§ 38.125(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, when measured on level ground, for a maximum rise of 3 inches, and the transition from station...
-
§ 38.83(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8 measured on level ground, for a maximum rise of 3 inches, and the transition from the station platform...
-
§ 38.95(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, when measured on level ground, for a maximum rise of 3 inches, and the transition from station...
-
General: ADA Standard Section 226.1
Section 226.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for dining surfaces and work surfaces.
-
11B-208.1 General
For the purposes of this section, electric vehicle charging stations are not parking spaces; see Section 11B-228. Exceptions: 1....
-
11B-208.1 General
For the purposes of this section, electric vehicle charging stations are not parking spaces; see Section 11B-228. Exceptions: 1....
-
Work Areas
Those used only by employees at a work station (janitor closets) or as part of a work area (stockroom shelves) are not required to comply (although work areas must be on an accessible route...
-
Chapter 10: Recreation Facilities
The final rule adds technical requirements to Chapter 10 for outdoor constructed features (1011); parking spaces within camping units and picnic units and pull-up spaces at dump stations...
-
Circulation Paths Serving Exempted Spaces [§203]
spaces, or very narrow passageways; employee work areas under 300 sq. ft. that are elevated at least 7” as an essential functional condition of the space (excluding raised courtroom stations...
-
Is compliance on both sides of a door or gate required when it is usable only from one side?
Examples include exit-only doors with no operating hardware on the exterior side or separate enter and exit fare gates in transit stations....
-
§ 38.53(d)(1) Requirements
Where new vehicles will operate in new stations, the design of vehicles shall be coordinated with the boarding platform design such that the horizontal gap between each vehicle door at rest...
-
§ 38.173(b)
(b) Where the vehicle covered by paragraph (a) will operate in an accessible station, the design of vehicles shall be coordinated with the boarding platform design such that the horizontal...
-
§ 38.125(b)(3) Emergency operation
The lift shall incorporate an emergency method of deploying, lowering to ground or station platform level with a lift occupant, and raising and stowing the empty lift if the power to the...
-
11B-228.1 General
Electric vehicle charging stations shall comply with Section 11B-228.3. Exception: Drive-up only depositories shall not be required to comply with Section 11B-309....
-
14 CFR Part 382 Nondiscrimination on the Basis of Disability in Air Travel (Air Carrier Access Act): Preamble and Section-by-Section Analysis (with amendments issued through July 2010)
Ashby, Deputy Assistant General Counsel for Regulation and Enforcement, Department of Transportation, 1200 New Jersey Ave., SE, Room W94-302, Washington, D.C., 20590 (202) 366-9310 (voice...
-
CONCLUSION
KIJEWSKI, Deputy Chief SHEILA M....
-
Dining Surface and Work Surface
In addition, the Board has indicated in the ADA scoping provisions that the types of work surfaces covered do not include those surfaces used by employees since elements of work stations...
-
Section 4.1.1, Application (Preamble, Section-by-Section Analysis)
any area used only as a work area (not just to areas ‘‘that may be used by employees with disabilities’’), and that the guidelines do not require that any area used as an individual work station...
-
Section 4.1.1, Application (Section-By-Section Analysis and Response to Comments)
any area used only as a work area (not just to areas "that may be used by employees with disabilities''), and that the guidelines do not require that any area used as an individual work station...
-
§ 38.125(b)(5) Platform barriers
The loading-edge barrier (outer barrier) which functions as a loading ramp when the lift is at ground or station platform level, shall be sufficient when raised or closed, or a supplementary...
-
11B-220.2 Point-of-sale devices
Point-of-sale devices at electric vehicle charging stations required to comply with Section 11B-812 shall comply with Section 11B-812.10.3....
-
§ 38.95(b)(5) Platform barriers
The loading-edge barrier (outer barrier) which functions as a loading ramp when the lift is at ground or station platform level, shall be sufficient when raised or closed, or a supplementary...