When ramps or bridgeplates are deployed, the walking surface shall be lighted with 2 foot-candles (22 lux) minimum of illumination....
Search Results "Curb Ramp Slope"
Commonly Searched Documents
-
T503.2 Ramps and Bridgeplates
-
Trail Grade
When expressed as a ratio of rise to length to the term used is running slope....
-
§ 36.403(e) Path of travel.
(e) Path of travel.
-
Sec.36.403(e) Path of travel
(e) Path of travel.
-
11B-505.10.1 Top and bottom extension at ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
11B-235.3 Boarding piers at boat launch ramps
Where boarding piers are provided at boat launch ramps, at least 5 percent, but no fewer than one, of the boarding piers shall comply with Section 11B-1003.3.2....
-
11B-235.3 Boarding piers at boat launch ramps
Where boarding piers are provided at boat launch ramps, at least 5 percent, but no fewer than one, of the boarding piers shall comply with Section 11B-1003.3.2. ...
-
11B-235.3 Boarding piers at boat launch ramps
Where boarding piers are provided at boat launch ramps, at least 5 percent, but no fewer than one, of the boarding piers shall comply with Section 11B-1003.3.2....
-
11B-405.7.2.1
Where the ramp width is less than the top landing width additional landing length may be necessary to accommodate handrail extensions required to be in the direction of the ramp run without...
- Sears Brands, LLC Craftsman Digital Torpedo Level
-
Wheelchair Spaces
Wheelchair spaces must be level (2% maximum slope in any direction) and adjoining routes and maneuvering spaces must provide flush connections so that maneuvering to and from spaces does...
-
11B-505.10.1 Top and bottom extension at ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
11B-505.10.1 Top and bottom extension at ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
1016.7.1 Maximum Running Slope and Segment Length
Table 1016.7.1 Maximum Running Slope and Segment Length Running Slope of Outdoor Recreation Access Route Segment Maximum Length of Segment...
-
1016.7.1 Maximum Running Slope and Segment Length
Table 1016.7.1 Maximum Running Slope and Segment Length Running Slope of Outdoor Recreation Access Route Segment Maximum Length of Segment Steeper than But...
-
10. Drinking fountains and water coolers
Accessible element or space ANSI A117.1 section APPLICATION 10. Drinking fountains and water coolers 4.15 Fifty percent of...
-
Newly Constructed Tabled Intersections That Contain Pedestrian Street Crossings With Yield or Stop Control (Section-by-Section Analysis)
Newly Constructed Tabled Intersections That Contain Pedestrian Street Crossings With Yield or Stop Control (Section-by-Section Analysis) The 2 percent maximum cross slope requirement...
-
405.1 General
Ramps on accessible routes shall comply with 405....
-
405.1 General
Ramps on accessible routes shall comply with 405....
-
Clear Width [§405.5]
Clear Width [§405.5] Ramp runs must have a clear width of 36” minimum (measured between handrails where provided)....
- Safepath EZ Edge™ Transition
-
405.1 General
Ramps on accessible routes shall comply with 405....
-
5.1.2 Level or Sloped Entry
Camp shelters providing roll-in access shall have a level or sloped entry that complies with the FSORAG Outdoor Recreation Access Route technical provisions if the camp shelter is in a campground...
-
11B-405.1 General
Ramps on accessible routes shall comply with Section 11B-405....