Thresholds and changes in level at doorways shall comply with Section 11B-404.2.5.
Search Results "Sliding Door"
-
11B-404.3.3 Thresholds
-
11B-404.3.3 Thresholds
Thresholds and changes in level at doorways shall comply with Section 11B-404.2.5.
-
§ 38.93(a)(2)
(2) If doorways connecting adjoining cars in a multi-car train are provided, and if such doorway is connected by an aisle with a minimum clear width of 30 inches to one or more...
-
11B-404.3.3 Thresholds
Thresholds and changes in level at doorways shall comply with Section 11B-404.2.5.
-
404.3.3 Thresholds
404.3.3 Thresholds. Thresholds and changes in level at doorways shall comply with 404.2.5
-
404.3.3 Thresholds
Thresholds and changes in level at doorways shall comply with 404.2.5.
-
404.2.8.2 Spring Hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
7d.
Is no more than 5 pounds force needed to push or pull open the accessible door?...
-
g-iv
Is no more than 5 pounds force needed to push or pull open the door?...
- S.66 Solid Wood Folding Door System Corner Detail
- Panda S.74 Aluminum Wood Clad Folding Door System
- Set Up and Adjustment of a PDQ Door Closer
-
7c.
Is there clear maneuvering floor space in front of each accessible door (see Figure 25 in the appendix for measurements) and on the pull side, is there at least 18 inches clear floor space...
-
Clear Width [4.13.5] and Vertical Clearance
Clear Width [4.13.5] and Vertical Clearance The clear width of the opening is measured from the face of the door in a 90 degrees open position to the opposite stop....
-
11B-809.8.4 Door signal devices
Every primary entrance to a residential dwelling unit with adaptable features shall be provided with a door buzzer, bell, chime or equivalent....
-
409.3.1 Power Operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in...
- S.74 Aluminum Wood Clad Folding Door System Corner Detail
- Panda TS.60 Thermally Broken Folding Door System Video 2
- Panda TS.60 Thermally Broken Folding Door System Video 1
-
Horton Automatics ICU/CCU Bi-Fold/Bi-Swing™ Door System
Requires the Premium User plan or above. (Login or upgrade your account!)
-
803 Dressing, Fitting, and Locker Rooms
In the proposed rule, an exception to this provision noted that a portion of this space (6 inches maximum) could extend under partitions or openings without doors that provide toe clearance...
-
§ 38.107(a)(5)
Door latches and hardware shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist....
-
11B-207.1 General
Doors that provide access only to interior or exterior stairways shall not be required to comply with Section 11B-404....
-
End-of-Row Stalls
If an out swinging door is provided at an end-of-row stall, maneuvering space of at least 18 inches at the latch side pull side must be provided....